Background

The authors evaluated the hemodynamic suppressive effects of xenon in combination with sevoflurane at skin incision in patients undergoing surgery.

Methods

Forty patients were assigned randomly to receive one of the following four anesthetics: 1.3 minimum alveolar concentration (MAC) sevoflurane, 0.7 MAC xenon with 0.6 MAC sevoflurane, 1 MAC xenon with 0.3 MAC sevoflurane, or 0.7 MAC nitrous oxide with 0.6 MAC sevoflurane (n = 10 each group). Systolic blood pressure and heart rate were measured before anesthesia, before incision, and approximately 1 min after incision.

Results

The changes in hemodynamic variables in response to incision were less with sevoflurane in combination with xenon and nitrous oxide than with sevoflurane alone. Changes in heart rate (in beats/min) were 19+/-11 (+/- SD) for sevoflurane alone, 11+/-6 for 0.7 MAC xenon-sevoflurane, 4+/-4 for 1 MAC xenon-sevoflurane, and 8+/-7 for nitrous oxide-sevoflurane. Changes in systolic blood pressure were 35+/-18 mmHg for sevoflurane alone, 18+/-8 mmHg for 0.7 MAC xenon-sevoflurane, 16+/-7 mmHg for 1 MAC xenon-sevoflurane, and 14+/-10 mmHg for nitrous oxide-sevoflurane.

Conclusions

Xenon and nitrous oxide in combination with sevoflurane can reduce hemodynamic responses to skin incision compared with sevoflurane alone. One probable explanation may be that xenon has analgesic properties similar to those of nitrous oxide, although the exact mechanism is yet to be determined.

WITH continued concerns about the use of nitrous oxide (N2O), [1-5]the interest in xenon anesthesia has increased. Xenon, a noble gas, possesses a clinically relevant anesthetic potency (minimum alveolar concentration [MAC]= 71%). [6,7]Its small blood-gas partition coefficient (0.115)[8]makes rapid induction and emergence possible. [9,10]Although its relatively high cost may limit clinical use, these properties, combined with the recent trend toward low-flow or closed-circuit anesthesia techniques, have caused anesthesiologists to reconsider using xenon.

The effects of surgical stimulation on the cardiovascular system during xenon anesthesia have been studied incompletely in humans. Several previous studies suggest that xenon causes minimal cardiovascular effects [11-13]and attenuates increases in plasma catecholamine associated with surgical stimulation. [11,12]However, medications such as pancuronium, fentanyl, or barbiturates were administered with xenon in these studies, [11-13]which may have affected the hemodynamic variables. [14,15]Furthermore, xenon was compared with N2O at unequianesthetic concentrations (1 MAC xenon vs. 0.7 MAC N2O), and the surgical stimulation was not controlled, [12,13]suggesting that the different level of anesthesia and stimuli might have confounded the results. Therefore, to evaluate rigorously the autonomic nervous system responses to surgical stimulation during xenon anesthesia, we conducted a randomized study by choosing equal MAC concentrations without any adjuvants.

After we received approval from the Institutional Human Studies Committee of Teikyo University, we obtained informed consent from 40 adult patients classified as American Society of Anesthesiologists physical status 1 or 2 and undergoing elective lower abdominal surgery. They were to have at least 5-cm skin incisions on the lower abdomen. Most of them were scheduled for either gynecologic or colorectal surgery. The patients scheduled for laparoscopic surgery were excluded because of its small skin incision. Other exclusion criteria were history of cardiac and pulmonary abnormalities, hypertension and use of medications that might affect blood pressure, heart rate (HR), and MAC values of inhaled anesthetics. Preanesthetic laboratory values were within normal limits.

No patient received any premedication. After the patients were in the operating room, monitoring by an electrocardiograph, a pulse oximeter, and a noninvasive blood pressure cuff was begun. Anesthesia was induced with single vital capacity inhalation of 5% sevoflurane, [16]and tracheal intubation was facilitated with 0.10 to 0.15 mg/kg vecuronium administered intravenously. Using a computer-generated random-number table, the patients were assigned to one of four groups receiving equal MAC (1.3 MAC) anesthetic treatment (n = 10 each per group): 1.3 MAC sevoflurane (sevoflurane group), 0.7 MAC xenon with 0.6 MAC sevoflurane (0.7 MAC xenon group), 1 MAC xenon with 0.3 MAC sevoflurane (1 MAC xenon group), and 0.7 MAC N2O with 0.6 MAC sevoflurane (N2O group). The MAC value of xenon was assumed to be 71% at age 43 yr. [7,17]The MAC values of sevoflurane, N2O, and xenon were adjusted to the patient's age using Mapleson's formula. [17]For the sevoflurane and N2O groups, the target end-tidal concentration was achieved by a fresh gas flow of 3 l/min. For the xenon groups, the residual sevoflurane administered during inhalation induction was adjusted to the target concentration (0.3 or 0.6 MAC) by high-flow oxygen (6 l/min) for at least 10 min. Then oxygen was discontinued and the upright ventilator bellows was deflated completely and refilled quickly with 100% xenon with sevoflurane. Xenon was started at 2 l/min. Two or 3 min later, when the end-tidal concentration reached 1 or 0.7 MAC, the xenon flow was reduced, oxygen was resumed, and the anesthesia system was closed. Respiratory gases were sampled at the Y connector, and inspired and expired sevoflurane, N2O, and carbon dioxide concentrations were monitored continuously using an infrared gas monitor (Ultima SV, Datex, Helsinki, Finland), which was calibrated just before each anesthetic with a tank standard. The xenon concentration was monitored continuously using a AZ720 xenon monitor (Anzai Medical, Tokyo, Japan), which used the absorption of a characteristic radiogram for the measurement. It was calibrated before each case using an 80% xenon-20% oxygen mixture analyzed to +/− 0.02% accuracy (Nihon-Sanso, Tokyo, Japan). The effective working range for this monitor was 1% to 100%, with an error +/− 1% and a 90% response time less than 1 s. The lungs were ventilated mechanically to maintain the end-tidal carbon dioxide concentration between 30 and 35 mmHg. No patient received any drugs other than those stated.

For approximately 30 min after tracheal intubation, the patients were left unstimulated except for positioning, preparation, and draping. The inhaled anesthetic concentrations remained stable at the target end-tidal concentration for at least 20 min before surgical incision. Heart rate and systolic blood pressure (SBP) were measured using a cuff with an automatic oscillographic method (Listmini BP-8800; Colin, Aichi, Japan) at the right arm before anesthesia was induced, 1 min before incision, at incision, and in “continuous” mode for 10 min thereafter. The Listmini BP-8800 can measure HR and SBP every 15-30 s in the continuous mode. The hemodynamic data were recorded on paper and analyzed by a person who was blinded to the anesthetic agents used. The SBP and HR before induction were recorded as the baseline hemodynamic variables. The SBP and HR at 1 min before incision were recorded as the hemodynamic variables during anesthesia. The peak SBP, which usually occurred 30 to 120 s after incision, and HR at the time were recorded as the hemodynamic variables at skin incision. All patients received approximately 10 ml [middle dot] kg-1[middle dot] h-1lactated Ringer's solution for the duration of this study. The procedures lasted approximately 45 min.

Statistical Analysis

Chi-squared analysis was applied to compare differences in gender and American Society of Anesthesiologists classification among the four groups. All the other numeric data were first analyzed with normal probability plots to evaluate the validity of the assumption that the populations are normally distributed. Because the normality assumption was not rejected in the demographic data and hemodynamic variables, they were analyzed using parametric tests. Demographic data were analyzed with one-way analysis of variance. Hemodynamic data were analyzed using one-way analysis of variance (between groups) and repeated-measures analysis of variance (within the group). Multiple comparisons of hemodynamic data were performed using Tukey's honestly significant difference test. [18,19]The data are reported as the mean +/− SD. P values < 0.05 were considered significant.

The four groups did not differ significantly with respect to gender, age, height, weight, American Society of Anesthesiologists classification, or hemodynamic variables before the administration of inhaled anesthetics (Table 1). No patient had an abnormal electrocardiogram or a pulse oximetry value less than 98% during the study period.

Table 1. Demographic Data and Baseline Hemodynamic Variables

Table 1. Demographic Data and Baseline Hemodynamic Variables
Table 1. Demographic Data and Baseline Hemodynamic Variables

Changes in Heart Rate

In the 0.7 and 1 MAC xenon groups, HR decreased significantly after anesthesia and remained at that level even after skin incision (92 +/− 22 beats/min at baseline, 70 +/− 17 beats/min before incision, and 81 +/− 15 beats/min after incision for 0.7 MAC xenon-sevoflurane; 78 +/− 14 beats/min at baseline, 63 +/− 10 beats/min before incision, and 67 +/− 9 beats/min after incision for 1 MAC xenon-sevoflurane). Heart rate remained stable after anesthesia and increased significantly after incision in the sevoflurane group, whereas HR decreased significantly after anesthesia and returned to the baseline level after incision in the N2O groups. The increases in HR at incision were significantly greater in the sevoflurane groups than in the 1 MAC xenon and N2O groups (change in HR: 19 +/− 11 beats/min for sevoflurane, 11 +/− 6 beats/min for 0.7 MAC xenon, 4 +/− 4 beats/min for 1 MAC xenon, and 8 +/− 7 beats/min for N2O [Figure 1]).

Figure 1. Changes in heart rate (HR; upper) and systolic blood pressure (SBP; lower) from before to after incision. Data are expressed as the mean +/− SD. [dagger] Significantly lower than the baseline within the group. [double dagger] Significantly higher than the baseline within the group. #Increase in HR significantly higher than in the 1 MAC xenon and N2O groups. *Increase in SBP significantly higher than the 0.7 MAC xenon, 1 MAC xenon, and N2O groups.

Figure 1. Changes in heart rate (HR; upper) and systolic blood pressure (SBP; lower) from before to after incision. Data are expressed as the mean +/− SD. [dagger] Significantly lower than the baseline within the group. [double dagger] Significantly higher than the baseline within the group. #Increase in HR significantly higher than in the 1 MAC xenon and N2O groups. *Increase in SBP significantly higher than the 0.7 MAC xenon, 1 MAC xenon, and N2O groups.

Close modal

Changes in Systolic Blood Pressure

In all four groups, SBP decreased after anesthesia and returned to the baseline level after skin incision. The increases in SBP at incision were significantly greater in the sevoflurane group than in the other three groups (change in SBP: 35 +/− 18 mmHg for sevoflurane, 18 +/− 8 mmHg for 0.7 MAC xenon, 16 +/− 7 mmHg for 1 MAC xenon, and 14 +/− 10 mmHg for N2O [Figure 1]).

Several lines of recent evidence suggest that volatile anesthetics, such as isoflurane, [20]cannot suppress hemodynamic responses to noxious stimuli. Zbinden et al. [20]showed that isoflurane cannot suppress hemodynamic reactions to painful stimuli; a normal blood pressure after stimulation can be achieved only if the prestimulation blood pressure is depressed to levels that may be clinically unacceptable. In contrast, supplementation with analgesics such as fentanyl and N2O enables these volatile anesthetics to attenuate hemodynamic responses. [21]These concepts have been confirmed and extended by our results, which showed that, although sevoflurane alone did not suppress SBP and HR changes at skin incision, a substitution of sevoflurane for N2O, an established analgesic, [22-26]or xenon can decrease hemodynamic changes. The opioid-like analgesic action of N2O was shown by previous studies, which reveal cross-tolerance between N2O and morphine [22]and partial reversal of N2O-induced antinociception by naloxone. [22-34]Nitrous oxide increases the brain tissue concentrations of opioid peptides such as [small beta, Greek]-endorphine, [25]although it does not interact directly with opioid receptors. [26] 

Furthermore, we have shown that xenon, similar to N2O, reduces hemodynamic responses to skin incision. Because xenon causes minimal cardiovascular depression and preserves myocardial contractility, [11,12,27-29]this N2O-like action of xenon can be attributed reasonably to its analgesic action. In fact, the analgesic properties of xenon have been suggested in humans and animals. Yagi et al. [30]reported a decreased incidence of pain during subanesthetic concentrations of xenon in human volunteers. Lachmann et al. [13]studied fentanyl requirements during 1 MAC xenon anesthesia and found that 80% of the patients required no fentanyl at skin incision to maintain their blood pressure within 20% of the baseline value. The mechanism of analgesic effects of xenon is described to be via suppression of spinal dorsal horn neurons [31]independent of [small alpha, Greek]2-adrenergicor opioid receptors [32]in experiments. These findings, in addition to our own, confirm the hypothesis that xenon possesses analgesic properties at clinically attainable concentrations in patients undergoing surgery.

Although the analgesic effect of xenon is likely to explain the similar hemodynamic response to incision between xenon and N2O, it may not be the only explanation. For example, the other possible interpretation of the blunted responses in patients receiving xenon might be that xenon has some direct action at neuroeffector junctions, such as the vagal or sympathetic interface with the sinoatrial node or with the peripheral vasculature. Because these properties of xenon have not been studied, further investigation is necessary to identify the exact mechanism of the reduced responses to incision.

We administered xenon and sevoflurane with a closed-circuit technique to minimize the cost of xenon. Our use of a closed-circuit technique might be criticized on two grounds. First, the accumulation of foreign gases during the closed-circuit technique theoretically may have affected the infrared gas monitor, thus making the measurement inaccurate. [33]Second, sevoflurane may cause adverse renal effects at low flows because it is degraded by the strong bases in carbon dioxide absorbents to compound A, which is a nephrotoxin in rats. [34,35]However, the accumulation of foreign gases and compound A is expected to be minimal because of the short duration of closed-circuit anesthesia in our investigation (< 30 min). Denitrogenation by the initial high-flow anesthesia further reduced the accumulation of foreign gases. Furthermore, recent investigations suggest that low-flow sevoflurane anesthesia does not cause clinically relevant renal dysfunction. [36,37]Therefore, we do not believe that use of the closed-circuit technique put the patients at risk of compromised the accuracy of gas measurement.

It is impossible to administer more than 1 MAC xenon (71%)[7]to patients undergoing surgery because of potential hypoxic complications. We arbitrarily considered the surgically adequate and ethically acceptable level of anesthesia to be 1.3 MAC, which represents an approximately 95% effective dose for movement at skin incision with isoflurane. [38]The interaction between xenon and halothane in their effect on MAC has been shown to be additive. [7]Assuming the similar additivity between xenon and sevoflurane, 1 MAC xenon with 0.3 MAC sevoflurane and 0.7 MAC xenon or N2O with 0.6 MAC sevoflurane are expected to represent 1.3 MAC. Therefore, we administered xenon with sevoflurane to ensure an adequate level of anesthesia, although we intended to evaluate the effects of surgical stimulation on the cardiovascular system during xenon anesthesia. Therefore, our results represent the combined effects of xenon and sevoflurane, rather than the effects of xenon alone, at skin incision. We do not believe that the use of vecuronium for neuromuscular blockade affected the results, because of the absence of cardiovascular effects of vecuronium. [15] 

In conclusion, xenon and N2O used with sevoflurane can reduce hemodynamic responses to skin incision compared with sevoflurane alone. One likely explanation may be that xenon possesses analgesic properties similar to N2O, although the exact mechanism is yet to be determined.

1.
Amos RJ, Amess JAL, Hinds CJ, Mollin DJ: Incidence and pathogenesis of acute megaloblastic bone-marrow changes in patients receiving intensive care. Lancet 1982; ii:835-9
2.
Layzer RB: Myeloneuropathy after prolonged exposure to nitrous oxide. Lancet 1978; ii:1227-30
3.
Weiss RF: The temporal and spatial distribution of tropospheric nitrous oxide. J Geophys Res 1981; 86:7185-95
4.
Kennedy RR, Stokes JW, Downing P: Anaesthesia and the 'inert' gases with special reference to xenon (review). Anaesth Intensive Care 1992; 20:66-70
5.
Lane GA, Nahrwold ML, Tait AR, Taylor-Busch M, Cohen PJ, Beaudoin AR: Anesthetics as teratogens: Nitrous oxide is fetotoxic, xenon is not. Science 1980; 210:899-901
6.
Cullen SC, Gross EG: The anesthetic properties of xenon in animals and human beings, with additional observations on krypton. Science 1951; 113:580-2
7.
Cullen SC, Eger EI, Cullen BF, Gregory P: Observations on the anesthetic effect of the combination of xenon and halothane. Anesthesiology 1969; 31:305-9
8.
Goto T, Suwa K, Uezono S, Ichinose F, Uchiyama M, Morita S: The blood-gas partition coefficient of xenon may be lower than generally accepted. Br J Anaesth 1998; 80:255-6
9.
Goto T, Saito H, Shinkai M, Nakata Y, Ichinose F, Morita S: Xenon provides faster emergence from anesthesia than does nitrous oxide-sevoflurane or nitrous oxide-isoflurane. Anesthesiology 1997; 86:1273-8
10.
Nakata Y, Goto T, Morita S: Comparison of inhalation inductions with xenon and sevoflurane. Acta Anaesthesiol Scand 1997; 41:1157-61
11.
Marx T, Froeba G, Wagner D, Baeder S, Goertz A, Georgieff M: Effects on haemodynamics and catecholamine release of xenon anaesthesia compared with total i.v. anaesthesia in the pig. Br J Anaesth 1997; 78:326-7
12.
Boomsma F, Rupreht J, Man in't Veld AJ, de Jong FH, Dzoljic M, Lachmann B: Haemodynamic and neurohumoral effects of xenon anaesthesia: A comparison with nitrous oxide. Anaesthesia 1990; 45:273-8
13.
Lachmann B, Armbruster S, Schairer W, Landstra M, Trouwborst A, Van Daal GJ, Kusuma A, Erdmann W: Safety and efficacy of xenon in routine use as an inhalational anaesthetic. Lancet 1990; 335:1413-5
14.
Klingstedt C, Giesecke K, Hamberger B, Jarnberg PO: High- and low-dose fentanyl anaesthesia: Circulatory and plasma catecholamine responses during cholecystectomy. Br J Anaesth 1987; 59:184-8
15.
Gregoretti SM, Sohn YJ, Sia RL: Heart rate and blood pressure changes after ORG NC45 (vecuronium) and pancuronium during halothane and enflurane anesthesia. Anesthesiology 1982; 56:392-5
16.
Yurino M, Kimura H: Vital capacity breath technique for rapid anaesthetic induction: Comparison of sevoflurane and isoflurane. Anaesthesia 1992; 47:946-9
17.
Mapleson WW: Effect of age on MAC in humans: A meta-analysis. Br J Anaesth 1996; 76:179-85
18.
Glantz SA, Slinker BK: Primer of Applied Regression and Analysis of Variance. New York, McGraw-Hill, 1990, pp 381-463
19.
Dawson-Saunders B, Trapp RG: Basic and Clinical Biostatistics. East Norwalk, CT, Appleton & Lange, 1990, pp 138-9
20.
Zbinden AM, Petersen-Felix S, Thomson DA: Anesthetic depth defined using multiple noxious stimuli during isoflurane/oxygen anesthesia. II. Hemodynamic responses. Anesthesiology 1994; 80:261-7
21.
Daniel M, Weiskopf RB, Noorani M, Eger EI II: Fentanyl augments the blockade of the sympathetic responses to incision (MAC-BAR) produced by desflurane and isoflurane. Anesthesiology 1998; 88:43-9
22.
Berkowitz BA, Ngai SH, Finck AD: Nitrous oxide 'analgesia': Resemblance to opiate action. Science 1976; 194:967-8
23.
Yang JC, Clark WC, Ngai SH: Antagonism of nitrous oxide analgesia by naloxone in man. Anesthesiology 1980; 52:414-7
24.
Zuniga JR, Joseph SA, Knigge KM: Nitrous oxide analgesia: Partial antagonism by naloxone and total reversal after periaqueductal gray lesions in the rat. Eur J Pharmacol 1987; 142:51-60
25.
Zuniga JR, Joseph SA, Knigge KM: The effects of nitrous oxide on the central endogenous pro-opiomelanocortin system in the rat. Brain Res 1987; 420:57-65
26.
Campbell DJ, Rowbotham DJ, Lambert DG: Do nitrous oxide and halothane influence opioid receptor binding in SH-SY5Y human neuroblastoma cells? Br J Anaesth 1995; 75:752-5
27.
Luttropp HH, Romner B, Perhag L, Eskilsson J, Fredriksen S, Werner O: Left ventricular performance and cerebral haemodynamics during xenon anaesthesia: A transesophageal echocardiography and transcranial Doppler sonography study. Anaesthesia 1993; 48:1045-9
28.
Luttropp HH, Thomasson R, Dahm S, Persson J, Werner O: Clinical experience with minimal flow xenon anesthesia. Acta Anaesthesiol Scand 1994; 38:121-5
29.
Morita S, Goto T, Niimi Y, Ichinose F, Saito H: Xenon produces minimal cardiac depression in patients under fentanyl-midazolam anesthesia (abstract). Anesthesiology 1996; 85:A363
30.
Yagi M, Mashimo T, Kawaguchi T, Yoshiya I: Analgesic and hypnotic effects of subanaesthetic concentration of xenon in human volunteers: Comparison with nitrous oxide. Br J Anaesth 1995; 74:670-3
31.
Utsumi J, Adachi T, Miyazaki Y, Kurata J, Shibata M, Murakawa M, Arai T, Mori K: The effect of xenon on spinal dorsal horn neurons: A comparison with nitrous oxide. Anesth Analg 1997; 84:1372-6
32.
Ohara A, Mashimo T, Zhang P, Inagaki Y, Shibuta S, Yoshiya I: A comparative study of the antinociceptive action of xenon and nitrous oxide in rats. Anesth Analg 1997; 85:931-6
33.
Versichelen L, Rolly G, Vermeulen H: Accumulation of foreign gases during closed-system anaesthesia. Br J Anaesth 1996; 76:668-72
34.
Eger EI, Koblin DD, Bowland T, Ionescu P, Laster MJ, Fang Z, Gong D, Sonner J, Weiskopf RB: Nephrotoxicity of sevoflurane versus desflurane anesthesia in volunteers. Anesth Analg 1997; 84:160-8
35.
Mazze RI, Jamison RL: Low-flow (1 l/min) sevoflurane: Is it safe (editorial)? Anesthesiology 1997; 86:1225-7
36.
Bito H, Ikeuchi Y, Ikeda K: Effects of low-flow sevoflurane anesthesia on renal function: Comparison with high-flow sevoflurane anesthesia and low-flow isoflurane anesthesia. Anesthesiology 1997; 86:1231-7
37.
Kharasch ED, Frink EJ, Zager R, Bowdle TA, Artru A, Nogami WM: Assessment of low-flow sevoflurane and isoflurane effects on renal function using sensitive markers of tubular toxicity. Anesthesiology 1997; 86:1238-53
38.
Zbinden AM, Maggiorini M, Petersen-Felix S, Lauber R, Thomson DA, Minder CE: Anesthetic depth defined using multiple noxious stimuli during isoflurane/oxygen anesthesia. I. Motor reactions. Anesthesiology 1994; 80:253-60