“Laboratories long ago resolved the problem of maintaining sterility … by buying prepackaged sterile supplies and introducing engineering controls at every possible step of the process. Is it time for the same in anesthesia?”

Image: ©Thinkstock.

IN this issue of Anesthesiology,1  we have a clear demonstration of a potential problem: bacterial contamination of IV injectates can happen (and frequently does, as demonstrated by the 6% rate of contamination found in this study and others2–4 ). The authors demonstrated that in real practice, bacteria and fungi can be recovered from the internal fluid path—intended to be sterile—of 6% of items (syringes and IV tubing) used in actual patient care. The authors combined two approaches to estimate the incidence of injectate microbial contamination: culturing the syringes prepared by providers and used to administer drugs and recovering for culture everything caught by a 0.2-μm filter placed in the fluid path downstream of all access points. This latter technique is ingenious because it allows capture (as well as identifies a potentially therapeutic interception) of all culturable microbes* injected intravenously during the course of the case. This approach allows cumulative measurement of the total contamination risk throughout the case. Combined analysis from the two sources demonstrates a high contamination rate in the injectates actually delivered to patients.

This study nicely illustrates the potential for lapses in basic infection control practices in the setting of a busy clinical practice. Strikingly, this 6% incidence may be lower than what occurs in usual practice, given that the participants were aware of the study aims and goals regarding culturing and investigating for contamination and may have been extra careful to follow good infection control practice. In other settings, anesthesia providers’ contaminated hands have been shown to be a significant source of intraoperative bacterial transmission to patients.5  In the spirit of fairness, breakdowns in infection control practices related to IV access and medication delivery are not unique to anesthesia professionals.

Clearly, this level of contamination raises a red flag. We do not know whether incidental injection of microbes is a major clinical source of infections, as the source of postoperative infections such as bacteremia is very challenging if not impossible to identify, and these infections may not be systematically tracked in healthcare settings. Most of the organisms identified are commensals found on skin and often have low pathogenic potential. In addition, the pathogenesis of surgical site infections (from direct wound inoculation as opposed to hematogenous seeding) calls into question the authors’ claim of injectate contamination as an important source of surgical site infections. That said, we do not have any evidence that it is safe to inject microorganisms either (and in fact have clear evidence of harm from other settings).

Neatly, we have in the same issue of Anesthesiology a report that describes a partial (but compelling due to its own workflow advantages) solution to the contamination problem: adoption of single-use, prefilled syringes.6  Reflecting on the typical drawer-to-arm workflow starting from a single-use drug vial and ending at the tip of a vascular catheter, professionally prepared, prefilled syringes eliminate about half of the potential opportunities to contaminate an IV solution: those occurring during the solution prep phase of the “prep → access IV → inject” process. Of course, prefilled syringes cannot prevent contamination due to poor IV access practices. Here, the 0.2-μm filter likely helps by reducing (though not eliminating) distal passage of bacteria and fungi (but not viruses).

From the purist’s perspective, some may argue that it is scientifically important to prove that accidental contamination of approximately 6% of all injectates with microorganisms is clinically meaningful. Prior work has demonstrated that the anesthesia work environment (patient, provider, and environs) becomes contaminated very quickly7  and that in some cases the bacterial type in subsequent infections matches that found in the work environment.2 

It is easy to understand that contamination of injectates occurs because of imperfect aseptic technique by providers. During patient care, IV injection ports inevitably contact the patient’s skin and other contaminated surfaces. Consequently, it is recommended to decontaminate IV injection ports before access because they must be assumed to be contaminated.

One of us (W.S.S.) actually uses this construct when educating trainees in aseptic technique: Unless one is working with sterile gloves in a sterile field, any sterile surface that is surrounded by an unsterile environment must be considered contaminated if the operator loses continuous visual confirmation that it has not contacted an unsterile object. Thus, it seems simple to educate clinicians to be careful to consistently use aseptic technique when preparing syringes and especially injecting into the IV, with the expectation that injectate contamination would cease to be a problem. (Cue: mild sarcasm.) As an optimistic example, hand hygiene success is associated with reduced anesthesia work environment contamination8  and reduced hospital infection rates.9  However, perfect hand hygiene performance is difficult to achieve and sometimes infeasible.8  Others may note that with the increasing turnover of healthcare providers and the growing burden of protocols, standards, and medical knowledge that clinicians must learn, we may not be able to reliably ensure adherence to basic practices 100% of the time. For instance, training of basic infection control practices is now relegated to instruction on the wards or clinics by clinical mentors/supervisors. With such diffusion of training, variability of practices invariably creeps in.

An alternative approach to the problem of injectate contamination may be via engineering controls: elements of the system that are inherently safer or more reliable because consistency or safeguards have been engineered in. Engineering controls such as disinfectable needleless injection ports can reduce contamination in IV injectates if the provider actually disinfects before injection.4  Replacing the provider as syringe preparer by a professional (or, increasingly, a computer-controlled robot) assigned only one task, operating in an optimal environment6  for microbial reduction is a strong engineering control. Adding the filter1  is also an engineering control that can reduce the microbial burden reaching the patient. To a specialty focused on reliability, safety, and engineered systems, such controls are appealing. However, these three elements likely add cost.

Given the almost negligible cost of both interventions (prefilled syringes and filters) relative to the cost of postoperative infections, should not we just implement? Such a proposal sets up a conflict between the drive for experimental rigor (the evidence-based medicine position: the cost of the infections should outweigh the cost of their prevention) versus the drive for sound, incremental improvement in the name of improving safety (the patient safety movement).10 

In patient care, the access points to IV systems are constantly out of sight. But beyond the theoretical likelihood of out of sight equals contaminated, we know IV access points really do become contaminated. We compensate by attempting to resterilize them before access. However, once we begin to access the IV system, even for routine activities such as induction of anesthesia, the rule of “out of sight implies contaminated” is difficult to operate by. It is even more difficult to live by in an emergency or under the drapes. Laboratories long ago resolved the problem of maintaining sterility in locally prepared items by buying prepackaged sterile supplies and introducing engineering controls at every possible step of the process. Is it time for the same in anesthesia?

Support was provided solely from institutional and/or departmental sources.

The authors are not supported by, nor maintain any financial interest in, any commercial activity that may be associated with the topic of this article.

*

There may be more microbial contaminants that cannot be cultured in vitro.

1.
Gargiulo
D
,
Mitchell
S
,
Sheridan
J
,
Short
T
,
Swift
S
,
Torrie
J
,
Webster
C
,
Merry
A
:
Microbiological contamination of drugs administered for anesthesia in the operating room: A prospective, open, microbiological audit.
Anesthesiology
2016
;
124
:
785
94
2.
Loftus
RW
,
Brown
JR
,
Patel
HM
,
Koff
MD
,
Jensen
JT
,
Reddy
S
,
Ruoff
KL
,
Heard
SO
,
Dodds
TM
,
Beach
ML
,
Yeager
MP
:
Transmission dynamics of Gram-negative bacterial pathogens in the anesthesia work area.
Anesth Analg
2015
;
120
:
819
26
3.
Loftus
RW
,
Koff
MD
,
Birnbach
DJ
:
The dynamics and implications of bacterial transmission events arising from the anesthesia work area.
Anesth Analg
2015
;
120
:
853
60
4.
Loftus
RW
,
Patel
HM
,
Huysman
BC
,
Kispert
DP
,
Koff
MD
,
Gallagher
JD
,
Jensen
JT
,
Rowlands
J
,
Reddy
S
,
Dodds
TM
,
Yeager
MP
,
Ruoff
KL
,
Surgenor
SD
,
Brown
JR
:
Prevention of intravenous bacterial injection from health care provider hands: The importance of catheter design and handling.
Anesth Analg
2012
;
115
:
1109
19
5.
Loftus
RW
,
Muffly
MK
,
Brown
JR
,
Beach
ML
,
Koff
MD
,
Corwin
HL
,
Surgenor
SD
,
Kirkland
KB
,
Yeager
MP
:
Hand contamination of anesthesia providers is an important risk factor for intraoperative bacterial transmission.
Anesth Analg
2011
;
112
:
98
105
6.
Yang
Y
,
Rivera
A
,
Fortier
C
,
Bernathy
J
:
A human factors engineering study of the medication delivery process during an anesthetic: Self-filled syringes versus prefilled syringes.
Anesthesiology
2016
;
124
:
795
803
7.
Loftus
RW
,
Koff
MD
,
Burchman
CC
,
Schwartzman
JD
,
Thorum
V
,
Read
ME
,
Wood
TA
,
Beach
ML
:
Transmission of pathogenic bacterial organisms in the anesthesia work area.
Anesthesiology
2008
;
109
:
399
407
8.
Rowlands
J
,
Yeager
MP
,
Beach
M
,
Patel
HM
,
Huysman
BC
,
Loftus
RW
:
Video observation to map hand contact and bacterial transmission in operating rooms.
Am J Infect Control
2014
;
42
:
698
701
9.
Talbot
TR
,
Johnson
JG
,
Fergus
C
,
Domenico
JH
,
Schaffner
W
,
Daniels
TL
,
Wilson
G
,
Slayton
J
,
Feistritzer
N
,
Hickson
GB
:
Sustained improvement in hand hygiene adherence: Utilizing shared accountability and financial incentives.
Infect Control Hosp Epidemiol
2013
;
34
:
1129
36
10.
Leape
LL
,
Berwick
DM
,
Bates
DW
:
What practices will most improve safety? Evidence-based medicine meets patient safety.
JAMA
2002
;
288
:
501
7