Background:

Reduced consumption of inhalation anesthetics can be safely achieved by reducing excess fresh gas flow (FGF). In this study the authors describe the use of a real-time decision support tool to reduce excess FGF to lower, less wasteful levels.

Method:

The authors applied a decision support tool called the Smart Anesthesia Manager™ (University of Washington, Seattle, WA) that analyzes real-time data from an Anesthesia Information Management System to notify the anesthesia team if FGF exceeds 1 l/min. If sevoflurane consumption reached 2 minimum alveolar concentration-hour under low flow anesthesia (FGF < 2 l/min), a second message was generated to increase FGF to 2 l/min, to comply with Food and Drug Administration guidelines. To evaluate the tool, mean FGF between surgical incision and the end of procedure was compared in four phases: (1) a baseline period before instituting decision rules, (2) Intervention-1 when decision support to reduce FGF was applied, (3) Intervention-2 when the decision rule to reduce flow was deliberately inactivated, and (4) Intervention-3 when decision rules were reactivated.

Results:

The mean ± SD FGF reduced from 2.10 ± 1.12 l/min (n = 1,714) during baseline to 1.60 ± 1.01 l/min (n = 2,232) when decision rules were instituted (P < 0.001). When the decision rule to reduce flow was inactivated, mean FGF increased to 1.87 ± 1.15 l/min (n = 1,732) (P < 0.001), with an increasing trend in FGF of 0.1 l/min/month (P = 0.02). On reactivating the decision rules, the mean FGF came down to 1.59 ± 1.02 l/min (n = 1,845). Through the Smart Anesthesia Messenger™ system, the authors saved 9.5 l of sevoflurane, 6.0 l of desflurane, and 0.8 l isoflurane per month, translating to an annual savings of $104,916.

Conclusions:

Real-time notification is an effective way to reduce inhalation agent usage through decreased excess FGFs.

What We Already Know about This Topic
  • Wasted anesthetic gases are expensive and can adversely affect the environment

  • One way to reduce excess anesthetic use is by minimizing excessive fresh gas flows

What This Article Tells Us That Is New
  • Real-time messages displayed by a decision support tool and the anesthesia information management system reduced the use of high fresh gas flows and anesthetic agents by anesthesia providers

  • Cost savings were noted

INCREASING expenses of health care have necessitated implementation of steps to contain costs and reduce waste. In the field of anesthesia, inhalation agents represent a major portion (20–25%) of the anesthetic drug costs,1–3  and the potential for cost savings by reducing the use of inhalation agents has been well documented.1–14  A sizable fraction of the administered inhalation agents is not absorbed by the patient, but rather is vented into the atmosphere through the waste gas scavenging system. The amount of wasted inhalation agent is directly correlated to the fresh gas flow (FGF).1,3,4,7  The use of a lower FGF setting has been proposed as a safe and effective way to minimize waste and contain cost.1,3,7,10,12  Adopting this strategy, the Departments of Anesthesiology and Pain Medicine and Pharmacy at our institution (University of Washington Medical Center, Seattle, Washington), embarked on a cost-saving initiative to reduce wastage of inhalation anesthetics.

Previous strategies to reduce FGF have included presenting individualized FGF patterns to anesthesia providers,9,13,14  sending e-mail reminders,15  and conducting practical training or education sessions on low flow anesthesia.7,10  Though such methods achieved moderate success in reducing FGF, sustained maintenance of low FGF could not be achieved because providers reverted to original behavior over time.5,10,13,14  In this study we describe the use of a real-time decision support tool to prompt practitioners to lower FGF to the lowest flow considered acceptable to the target users, consistent with the recommendations for reducing FGF. The decision support tool called Smart Anesthesia Manager™ (SAM), a custom software application developed at University of Washington, works in conjunction with an Anesthesia Information Management System (AIMS) to notify the anesthesia provider concerning issues related to quality of care, billing, and compliance in real time. SAM’s decision support rules were enhanced to add notifications for reducing FGF to the lowest levels considered acceptable to the target users during the maintenance phase of anesthesia.

The efficacy of real-time decision support to reduce and maintain FGF at the desired level was evaluated through a prospective study that used an interrupted time series approach. First, baseline data were collected for 2 months on FGF patterns immediately before any intervention. Then, the newly created SAM decision rules were activated for a period of 2.5 months. As a second intervention, to assess the true effect of decision support, the SAM messages to reduce FGF were inactivated for 2 months. In the third intervention, the rules were reactivated.

AIMS and Data Acquisition

In 2008, to improve clinical documentation, quality of care, and billing, our institution installed an AIMS system (Docusys/Merge AIMS; Merge Inc., Hartland, WI). The AIMS was configured to automatically acquire hemodynamic and ventilation parameters from the patient monitor and anesthesia machine every minute and record them as part of the anesthesia record. Minute-by-minute data acquisition of end-tidal inhalation agent concentration for the three anesthetic agents—sevoflurane, desflurane, and isoflurane; gas flows of oxygen, air, and nitrous oxide were included as part of this interface. By adding together the individual minute-by-minute gas flows, we could compute total FGF every minute. During our initial assessment phase before September 2010, not all anesthesia machines in our operating rooms (ORs) had the capability to measure gas flows. However, during July–September 2010, older anesthesia machines were progressively replaced by newer models that had the capability to measure gas flows. Starting September 1, 2010, all ORs had the capability to measure gas flows.

Initial Assessment of Inhalation Agent Usage

To begin with, we conducted a baseline analysis of the usage of inhalation agents in our institution. This allowed us to understand the existing pattern of inhalation agent usage and provide a basis to formulate future intervention steps to reduce wastage of inhalation agents. After Institutional Review Board (University of Washington, Seattle, WA) approval, data were extracted from the AIMS database for 2 months (July 1, 2010–August 31, 2010). Specifically, minute-by-minute end-tidal inhalation agent concentration and FGF data were extracted for cases in which both these parameters were measured (~50% of the total number of general anesthesia cases had gas flows measured during this period). Additionally, demographic data related to the surgery, such as procedure start time, procedure end time, procedure type, and description were also extracted. For each general anesthesia case, average FGF was computed by integrating minute-by-minute FGF between procedure start and end times, and dividing by the procedure duration. From the average FGF for each case, mean FGF across all general anesthesia cases was determined. In addition, cases were classified based on the type of inhalation agent used (sevoflurane, desflurane, and isoflurane) and the mean FGF among cases using the same inhalation agent was calculated. The minute-by-minute samples of FGF greater than 2 l/min were used to compute the number of minutes when FGF was set greater than 2 l/min for each case. The total time in minutes when FGFs were greater than 2 l/min between start and end of procedure were calculated for all cases and divided by the total procedure duration for all cases to determine the fraction of time when FGF was greater than 2 l/min. The initial assessment data are summarized in table 1. The mean FGF for all cases in our institution was 2.27 l/min, with sevoflurane being the predominantly used agent (68%). Approximately 50% of the cases had a mean FGF of greater than 2.0 l/min, and FGF was set greater than 2.0 l/min 45% of the time in all cases. On the basis of this initial assessment, we formulated a proposal to reduce inhalation agent waste by reducing FGF. The baseline data were not included in the study because not all ORs had the capability to measure FGF during this phase.

Table 1.

Initial Assessment Summary (July 1, 2010–August 31, 2010)

Initial Assessment Summary (July 1, 2010–August 31, 2010)
Initial Assessment Summary (July 1, 2010–August 31, 2010)

Proposal to Reduce Inhalation Agent Waste

To reduce wastage of excess agents, we proposed the use of lower FGFs within the limits recommended by the Food and Drug Administration.** Specifically, the Food and Drug Administration recommends that to minimize exposure to compound A, sevoflurane exposure should not exceed 2 minimum alveolar concentration (MAC)-h at flow rates of 1 to less than 2 l/min and that FGF rates less than 1 l/min are not recommended. Conversely, warnings have not been issued for desflurane and isoflurane usage. Considering these guidelines, we proposed a plan to use 1 l/min FGF during the maintenance phase of anesthesia for desflurane and isoflurane. For sevoflurane, we proposed using an FGF of 1 l/min for the first 2 MAC-h and subsequently increasing the flow to 2 l/min. The proposed plan was presented to the anesthesia faculty through an e-mail discussion forum and received approval from the Department of Anesthesiology and Pain Medicine.

SAM Decision Support

To introduce, enforce, and maintain the plan to reduce FGF, a real-time decision support tool, SAM, was used. SAM is a real-time decision support tool that works alongside the AIMS. SAM was internally developed by the University of Washington to improve quality of care, anesthesia professional services billing, and compliance.16,17  SAM acquires AIMS data in near real-time, processes it to identify clinical, billing, or compliance issues, and notifies the anesthesia provider. SAM was enhanced to add decision rules related to FGF. Specifically, SAM rules were created to remind the anesthesia provider to reduce FGF to 1 l/min after the start of surgical procedure (incision). For cases that used sevoflurane, once the usage has reached 2 MAC-h under low flow conditions (FGF < 2 l/min), a second reminder was generated to increase the flow to 2 l/min. To obtain low flow sevoflurane usage, MAC-adjusted expired sevoflurane fraction (expired % of sevoflurane/2.05) was integrated for those samples that had the corresponding FGF values less than 2 l/min. The messages were conveyed to the anesthesia provider via “pop-up” messages overlaid on top of the AIMS screen as shown in figure 1.

Fig. 1.

SAM message to reduce FGF overlaid on top of AIMS (anesthesia information management system) screen. The FGF value is computed by adding individual flows of oxygen, air, and nitrous oxide. FGF = fresh gas flow; SAM = Smart Anesthesia Manager™, University of Washington Medical Center, Seattle, WA.

Fig. 1.

SAM message to reduce FGF overlaid on top of AIMS (anesthesia information management system) screen. The FGF value is computed by adding individual flows of oxygen, air, and nitrous oxide. FGF = fresh gas flow; SAM = Smart Anesthesia Manager™, University of Washington Medical Center, Seattle, WA.

Close modal

Evaluation of real-time decision support to reduce FGF was designed as a prospective study consisting of four phases. They include one baseline phase and three interventions phases. The evaluation was initiated after all ORs had the capability to measure FGF.

Preintervention Baseline (September 15, 2010–November 15, 2010)

Before introducing the new SAM messages, we chose 2 months (September 15, 2010–November 15, 2010) immediately before intervention to serve as a baseline period. All ORs of our hospital were configured to measure FGF before this period. A baseline period contiguous with the subsequent intervention periods was deliberately chosen to minimize the probability of any extraneous factors affecting the comparison of results obtained from the different phases.

Initial Go-live of SAM Rules and Their Refinement (November 17, 2010–November 30, 2010)

Without any additional training, the anesthesia providers were notified of the new SAM rules via an e-mail message and an announcement during a departmental conference. Subsequently, the newly added decision rules on FGF were activated. Messages were generated every 6 min just after the start of the surgical procedure (incision) until the end of surgery (closing), based on the decision logic described previously. The system was closely monitored to make sure that the messages were generated accurately. We noticed that with a messaging frequency of once every 6 min, a high frequency of messages (three to four messages/case to reduce flow) was generated, which was distracting to the users. Also, the first message was sent immediately after the start of the procedure when the anesthesia provider was busy making the final adjustments toward the maintenance phase of anesthesia. On the basis of these observations and user feedback from the anesthesia providers, the notification strategy was refined to reduce information overload, exclude nonapplicable periods or cases, and remind users to increase flow in case the FGF is set significantly below the recommended level. The final set of rules is outlined in table 2. In the final set of rules, the first message to reduce FGF was generated 10 min after the start of surgical procedure (incision), to give a buffer period during which the anesthesia provider can make final adjustments to FGF in preparation for the maintenance phase of anesthesia. In addition, we established a documentation feature that allowed the provider to record whether FGF could not be reduced for a medical reason (e.g., nitric oxide being used). If there is documentation that FGF could not be reduced for a specific reason, the decision support to reduce FGF is disabled for that case.

Table 2.

Final Set of FGF Decision Rules in SAM

Final Set of FGF Decision Rules in SAM
Final Set of FGF Decision Rules in SAM

Intervention-1: Activation of SAM Messages (December 1, 2010–February 14, 2011)

The refined SAM decision rules were activated on December 1, 2010, with no further announcement to the anesthesia providers. The decision rules and the associated messages were kept constant and continued for 2.5 months.

Intervention-2: Inactivation of Some SAM Messages (February 15, 2011–April 14, 2011)

To independently evaluate the impact of the SAM messages, the message to reduce FGF was deliberately turned off without notifying the anesthesia providers. However, the other messages related to FGF (messages FGF2 and FGF3) continued to be active during this period. Intervention-2 was applied for 2 months.

Intervention-3: Reactivation of All SAM Messages (April 15, 2011–June 14, 2011)

At the end of the previous intervention, the inactive SAM message was reactivated so that the exact same messages generated during Intervention-1 were restored. Similar to the previous intervention, no notification or announcement was issued before this intervention as well.

Data Preparation

After obtaining Institutional Review Board approval, minute-by-minute FGF and end-tidal inhalation agent concentration values, surgical procedure start time (incision time) and surgical procedure end time were extracted from the AIMS database for the baseline and intervention periods. Mean FGF and duration of each anesthetic agent usage between procedure start and end times were computed. Moreover, surgery-related information such as date of surgery, type, and duration of surgical procedure, and OR location were also extracted from the AIMS database. In addition to the data extracted from the AIMS database, an audit of the inhalation agents’ stock was performed by the Department of Pharmacy. Specifically, at the start and end of a new intervention, the current stock of agent bottles in all the ORs and satellite pharmacy was audited. To calculate the agent consumption during an intervention, the agent stock at the end of the intervention was subtracted from the sum of the agents purchased and the OR/Pharmacy stock at the start of the intervention. However, for the baseline period, we did not perform the aforementioned audit as the study has not been initiated. Hence, the baseline consumption was obtained from the Department of Pharmacy, which keeps information on agent purchase and average consumption of inhalation agents.

Statistical Analysis

Descriptive statistics for the procedure variables were calculated for each of the four phases to verify that the phases were matched with respect to these variables. These variables include the proportion of cases by different anesthetic agents, the proportion of cases by procedure type, and the mean ± SD of the procedure duration. Differences between pairs of phases in these variables were tested by the two-sided chi-square test and by the two-sided two-sample t test with unequal variances. To compare different phases, the mean and standard variation of the primary variable − FGF were computed for each phase. Mean FGF was compared between pairs of phases by the two-sided two-sample t test with unequal variances. The difference in mean FGF between pairs of phases and the 95% CI for the difference were calculated. This comparison was done for all cases as well as separately for sevoflurane, desflurane, and isoflurane cases.

Temporal trend in mean FGF across the four phases was visualized by plotting the procedure date against the mean FGF. Loess smoother18  was fit separately for each period to estimate the temporal trend within that period. The smoothing parameter α was set to 1.2 for all four phases. For the intermediate, trial period between baseline and Intervention-1 period α was set to 2. We tested for a monotonous trend within each phase using linear regression of the mean FGF against the procedure date. The slope of the trend was expressed in terms of a change in FGF per month.

All calculations were carried out in R statistical software (R Foundation for Statistical Computing, Vienna, Austria), version 2.13.0. A P value less than 0.05 was used to denote statistical significance.

For each of the four phases of the study, the number of cases, distribution of case types, distribution of inhalation agents used, and the mean procedure duration were similar (table 3).

Table 3.

Case and Agent Distribution among Cases during the Four Phases of the Study

Case and Agent Distribution among Cases during the Four Phases of the Study
Case and Agent Distribution among Cases during the Four Phases of the Study

The comparison of mean FGF values for the four phases of the study is shown in table 4. The mean ± SD of FGF for all cases reduced from a baseline value of 2.10 ± 1.12 l/min to 1.60 ± 1.01 l/min (P < 0.001) when SAM decision rules were activated during Intervention-1. However, when the messages to reduce flow were inactivated in Intervention-2, the mean ± SD of FGF increased to 1.87 ± 1.15 l/min (P < 0.001). When the messages to reduce flow were reactivated, the mean ± SD of FGF reduced to 1.59 ± 1.02 l/min, a value similar to Intervention-1 (mean Intervention-1 FGF vs. mean Intervention-3 FGF: P = 0.7). Sevoflurane and isoflurane cases showed a similar pattern for all the four phases. However, for desflurane cases, though the FGF reduced from a baseline value of 1.51 ± 0.89 l/min to 1.30 ± 0.82 l/min during Intervention-1 (P < 0.001), when the SAM messages to reduce flow were turned off (Intervention-2) FGF increased only marginally to 1.43 ± 1.00 l/min, with the change not statistically significant (P = 0.07).

Table 4.

Cumulative and Agent Specific Mean FGF for Each Phase of the Study; and the FGF Comparison between Baseline Are Intervention Periods

Cumulative and Agent Specific Mean FGF for Each Phase of the Study; and the FGF Comparison between Baseline Are Intervention Periods
Cumulative and Agent Specific Mean FGF for Each Phase of the Study; and the FGF Comparison between Baseline Are Intervention Periods

In addition to static analysis, we conducted a trend analysis to evaluate the change in mean FGF over time during the four phases of the study. Figure 2 shows how the cumulative FGF varied within and across the four phases. In figure 2, the individual points represent the mean FGF for each case. The solid colored lines are the smoothed trends in the mean FGF values, whereas the colored band around the solid line represents the 95% CI for the mean FGF. The difference in the mean trends during the baseline and Intervention-1 phases shows that the FGF dropped abruptly upon initiating the real-time decision support messages at the start of Intervention-1. The mean FGF during Intervention-1 phase increased only slightly (slope = +0.068 l/min/month, P = 0.02) in spite of personnel changes as part of new resident rotations. However, when the messages to lower FGF were inactivated (Intervention-2), the mean FGF increased in a more rapid fashion (slope of + 0.105 l/min/month; P = 0.03). Toward the end of Intervention-2, the FGF levels reached a value (2.10 ± 0.08 l/min, Loess Smoother) very similar to baseline FGF (2.10 ± 1.12 l/min). Mean FGF came down to a very similar level as with Intervention-1 when the messages were reactivated during Intervention-3.

Fig. 2.

Trend in mean FGF from September 15, 2010 to June 14, 2011: A smoothed version of FGF trend is shown in which Loess smoother was used individually for each period. The smoothing parameter α was equal to1.2 except for the intermediate period between baseline and the Intervention-1 period when α was set to 2. The gray circles represent the mean FGF for each case. The times when resident personnel changes occurred during Intervention-2 and Intervention-3 are shown with the help of red arrows. FGF = fresh gas flow.

Fig. 2.

Trend in mean FGF from September 15, 2010 to June 14, 2011: A smoothed version of FGF trend is shown in which Loess smoother was used individually for each period. The smoothing parameter α was equal to1.2 except for the intermediate period between baseline and the Intervention-1 period when α was set to 2. The gray circles represent the mean FGF for each case. The times when resident personnel changes occurred during Intervention-2 and Intervention-3 are shown with the help of red arrows. FGF = fresh gas flow.

Close modal

For cases that last more than 3 h, the time trend of FGF for each of the inhalation agents for the first 2.5 h after procedure start is shown in figure 3. The FGF was averaged across cases for each time sample. Figure 3 shows the pattern of FGF adjustments in response to SAM messages. The first SAM message to reduce FGF appeared within a time window of 10–22 min (10-min delay built into the rules plus 12 min sampling period for FGF messages) after procedure start. It is during the period from procedure start to approximately 20 min after that the most reduction in FGF was observed. For desflurane and isoflurane, the FGF rates were kept constant after they were reduced from induction levels. However, for sevoflurane, the anesthesia provider increased the flow to 2 l/min when the anesthetic agent consumption reached 2 MAC-h under low flow condition. This action by the anesthesia provider is in response to the SAM message that notifies the provider when 2 MAC-h of sevoflurane have been delivered with FGF level below 2 l/min.

Fig. 3.

Average minute-by-minute trend of FGF adjustment between procedure start and end for each inhalation agent is shown. The average was determined across cases for each time sample. The first SAM message to reduce flow is triggered between 10 and 22 min (highlighted in light blue) after start of procedure (marked time “0” in the graphs). For sevoflurane, a second message is triggered to increase flow to 2 l/min when agent consumption under low flow conditions (<2 l/min) has reached 2 MAC-h. The period when the second message is triggered is marked in light purple. FGF = fresh gas flow; MAC = minimum alveolar concentration; SAM = Smart Anesthesia Manager™, University of Washington Medical Center, Seattle, WA.

Fig. 3.

Average minute-by-minute trend of FGF adjustment between procedure start and end for each inhalation agent is shown. The average was determined across cases for each time sample. The first SAM message to reduce flow is triggered between 10 and 22 min (highlighted in light blue) after start of procedure (marked time “0” in the graphs). For sevoflurane, a second message is triggered to increase flow to 2 l/min when agent consumption under low flow conditions (<2 l/min) has reached 2 MAC-h. The period when the second message is triggered is marked in light purple. FGF = fresh gas flow; MAC = minimum alveolar concentration; SAM = Smart Anesthesia Manager™, University of Washington Medical Center, Seattle, WA.

Close modal

The audit of actual agent consumption performed by the pharmacy department is shown in table 5. Monthly consumption was reduced by 38 bottles for sevoflurane, 25 bottles for desflurane, and 8 for isoflurane when SAM decision support messages were activated. This translated to $104,916 of annual savings at our institution. As is evident from table 4, when decision support to reduce FGF was inactivated during Intervention-2, the agent consumption increased. When the decision support was reactivated in Intervention-3, the agent consumption levels returned to approximately the same levels as in Intervention-1.

Table 5.

Consumption of Inhalation Agents during the Four Phases of the Study Obtained through Auditing Pharmacy Supply Stock

Consumption of Inhalation Agents during the Four Phases of the Study Obtained through Auditing Pharmacy Supply Stock
Consumption of Inhalation Agents during the Four Phases of the Study Obtained through Auditing Pharmacy Supply Stock

Reducing wastage of inhalation anesthetic agents by minimizing FGF is a safe and established strategy to contain cost. Unlike previous attempts that focused on providing retrospective feedback in the form of e-mail reminders15  and reports,13,14  we used a real-time decision support system, SAM, to alert the anesthesia provider that the FGF may be excessive. This approach has several advantages. Most notably, real-time notification elicits real-time response from the care provider, thus allowing adjustments to FGF in real time. Additionally, an automated system such as SAM obviates the need for manual and resource-intensive interventions such as retrospective report generation and announcements.

Real-time decision support through AIMS add-on software had been developed by others previously.19–23  These attempts also focused on solving issues related to billing19–21  and quality of care.22,23  SAM is a similar software tool that was developed with University of Washington resources to interface with the AIMS system used in our hospital. SAM is a low-cost and low-maintenance software that shares hardware with an AIMS system. It runs in the background, with minimal interaction with AIMS, detecting and notifying issues concerning quality of care, billing, and compliance. For this study, SAM was enhanced to provide decision support toward reduction of inhalation agent wastage. To the best of our knowledge, this is the first attempt at reducing agent wastage, using an AIMS-based real-time decision support. However, an anesthesia machine specific tool, the Low Flow Wizard (LFW; Dräger, Lübeck, Germany), exists for real-time optimization of FGF, but the effectiveness of this system has not been rigorously documented.

In this study, for safety reasons, we chose to adhere with the current Food and Drug Administration recommendations (only for the United States) for FGF levels when using various inhalation agents. Though no specific lower limit for FGF is recommended for desflurane and isoflurane, we used a target of 1 l/min as a compromise between the need to change anesthetic levels rapidly and minimizing agent wastage.24  However, for sevoflurane, Food and Drug Administration recommends that low flow anesthesia (1 l/min) be maintained only for 2 MAC-h of agent consumption, to minimize exposure to compound-A. However, interestingly, more recent studies have indicated that compound-A toxicity has not been detected in humans.24,25 

The goal of our study was to change institutional behavior and patterns in managing FGF in an attempt to reduce wastage of inhalation agents. For this reason, we did not analyze provider-level behaviors toward adjusting FGF. However, the time trends of FGF changes during Intervention-2 and Intervention-3 (fig. 2) provide some indication of the effect that real-time decision had on the anesthesia personnel’s behavior when adjusting FGF. When the real-time reminder to reduce FGF was turned off during Intervention-2, the behavior to reduce flow ingrained through SAM messages during Intervention-1 slowly began to wane. When providers (residents mainly) were rotated, it seemed to have accelerated the group behavior toward baseline practice, when SAM was not used. Reactivating the SAM messages to reduce FGF in Intervention-3 seemed to have brought the desired behavior back almost instantaneously in spite of personnel change.

The average time trend showing FGF adjustments between procedure start and end (Figure 3) highlights how closely real-time decision support can guide anesthesia providers to adhere to a desired behavior. As can be observed in figure 3, the first notification to reduce FGF is generated within a time window of 10–22 min after procedure start. This is based on the delay of 10 min built into the decision logic to initiate FGF messages and the sampling time of SAM (12 min). Anesthesia providers reduced the FGF setting to the target level (1 l/min with a tolerance of 0.2 l/min) for all agents within the 10–22 min time window. For both desflurane and isoflurane, the FGF values were kept the same for the remainder of the procedure. However, for sevoflurane, a second message to return flow to 2 l/min after 2 MAC-h of low flow agent consumption, produced an FGF adjustment to 2 l/min. Because 2 MAC-h consumption is dependent on the agent concentration and FGF, the actual reminder to increase FGF to 2 l/min was generated not after exactly 2 h of reducing the flow, but rather over a period of 120–160 min after the start of procedure.

Though the target value of FGF was 1 l/min, the average FGF that was achieved with real-time decision support was 1.6 l/min. Several factors could have contributed to this higher-than-expected result. First, the average FGF was computed as the average value of the mean FGF between procedure start and end of each case. As can be seen from figure 3, in general, providers brought down the FGF to the target level during a time period of 10–22 min after the start of procedure. Additionally, for cases of short duration, the fraction of time between the start and end of procedure when FGF could be maintained at the target level was small. Because of the delay in reducing FGF and because we did not exclude short-duration cases, the mean FGF computed across all cases was higher than the target level of 1 l/min.

For some cases FGF could not be reduced for a medical reason such as the use of nitric oxide. The AIMS note to document this aspect was implemented on December 1, 2010 at the start of Intervention-1. During the remainder of the study (December 1, 2010– June 14, 2011, i.e., 6.5 months) only 76 cases of 5,840 general anesthesia cases (1.3%) had documented that FGF could not be lowered for a medical/technical reason. Of the 76 instances, 58% of the time, it was because nitric oxide was used, 4% because of leaks, and 38% because of other reasons, which we could not identify. Though we could identify such cases in the AIMS database after we instituted the FGF decision rules, it proved difficult to identify similar cases during the baseline period because the necessary AIMS note was not available before December 1, 2010. For this reason and because these cases constitute a small fraction (1.3%), we did not exclude these cases from the analysis.

Subsequent to the completion of the study, we kept the SAM rules to lower FGF activated, and these rules are still being used in daily practice at our institution. Interestingly, the mean ± SD FGF for the postintervention period from July 2011 to December 31, 2011 (6 months) was 1.37 ± 0.76 l/min, lower than value of 1.60 ± 1.01 l/min observed during Intervention-1 when the SAM messages were initially activated. This observation possibly indicates the positive long-term benefit of decision support toward ingraining desired provider behavior.

The decision support used in this study was meant to meet our goal to have a fairly simple, yet unobtrusive, method to remind anesthesia providers to lower FGF and hence to reduce wastage of anesthetic agents. However, future enhancements can further improve the system. Specifically, by the comparison of inspired and expired anesthetic agent concentration the onset of maintenance can be better identified, resulting in a better trigger for SAM notifications. In addition, rather than a fixed target for FGF, more optimal, case by case targets could be adopted to improve SAM decision support.

Actual cost savings due to a reduction of FGF at a particular institution will depend on the baseline inhalation agent usage and FGF settings. In our institution, a large academic medical center, the average FGF was 2.1 l/min. Observational studies5,9  have reported a similar value at other academic medical centers. However, other institutions have also reported higher FGF rates in the range of 3–4 l/min.2,10,12  The higher the preintervention FGF, the more savings the institution can expect through real-time decision support. In our institution, sevoflurane and then desflurane were the main inhalation agents of choice, with much less expensive isoflurane used less than 10% of the time. It could be argued that additional economic savings could be achieved if we had encouraged usage of isoflurane in place of sevoflurane or desflurane. Though we plan to do this as a future step, as the first attempt at applying decision support to optimize inhalation agent cost savings, we chose an approach, that is, reduction of excess FGF, with little impact on clinical practice.

The audit of anesthetic agent consumption had some limitations. There could have been residual amounts of anesthetic agents in the vaporizers, which we did not measure and account for in the waste calculation. Because the number of ORs and hence anesthesia machines remained the same during the period of the study we assumed that the residual agent in the vaporizers was approximately a constant factor at the start and end of each intervention. Additionally, for the baseline period before initiating the study, we did not perform an audit, but rather used the average inhalation agent consumption information obtained from the Department of Pharmacy.

It is important to note that our method to reduce FGF through real-time notification will only work if the anesthesia machines are equipped to measure and export FGF. Additionally, the AIMS system should be capable of recording FGF information. Most new anesthesia machines are capable of measuring and exporting FGF data to an AIMS. In a recent article that discussed strategies of managing FGF, Feldman26  highlights emerging technologies related to anesthesia delivery system, which makes it possible to use low FGFs in closed-circuit anesthesia. However, such technologies are expensive and require specialized anesthesia machines. In comparison, our method of using real-time decision support to optimize FGF is simpler and far less expensive.

In summary, our study was able to demonstrate the usage of a real-time decision support tool to change and maintain the behavior of anesthesia providers toward adopting low FGF when using inhalation agents. In terms of usage, this effort translated to a 28% reduction in sevoflurane, 33% reduction in desflurane, and a 12% reduction in isoflurane.

**

Food and Drug Administration Guidelines: http://www.accessdata.fda.gov/drugsatfda_docs/label/2006/020478s016lbl.pdf. Accessed June 15, 2012.

1.
Odin
I
,
Feiss
P
:
Low flow and economics of inhalational anaesthesia.
Best Pract Res Clin Anaesthesiol
2005
;
19
:
399
413
2.
Euliano
TY
,
van Oostrom
JH
,
van der Aa
J
:
Waste gas monitor reduces wasted volatile anesthetic.
J Clin Monit Comput
1999
;
15
:
287
93
3.
Suttner
S
,
Boldt
J
;
Low-flow anaesthesia
:
Does it have potential pharmacoeconomic consequences?
Pharmacoeconomics
2000
;
17
:
585
90
4.
Golembiewski
J
:
Economic considerations in the use of inhaled anesthetic agents.
Am J Health Syst Pharm
2010
;
67
(
8 Suppl 4
):
S9
12
5.
Dexter
F
,
Maguire
D
,
Epstein
RH
:
Observational study of anaesthetists’ fresh gas flow rates during anaesthesia with desflurane, isoflurane and sevoflurane.
Anaesth Intensive Care
2011
;
39
:
460
4
6.
Weinberg
L
,
Story
D
,
Nam
J
,
McNicol
L
:
Pharmacoeconomics of volatile inhalational anaesthetic agents: An 11-year retrospective analysis.
Anaesth Intensive Care
2010
;
38
:
849
54
7.
Ryu
HG
,
Lee
JH
,
Lee
KK
,
Gil
NS
,
Kim
CS
,
Sim
SE
,
Lee
SC
,
Min
SW
:
The effect of low fresh gas flow rate on sevoflurane consumption.
Korean J Anesthesiol
2011
;
60
:
75
7
8.
Lockwood
GG
,
White
DC
:
Measuring the costs of inhaled anaesthetics.
Br J Anaesth
2001
;
87
:
559
63
9.
Kennedy
RR
,
French
RA
:
Changing patterns in anesthetic fresh gas flow rates over 5 years in a teaching hospital.
Anesth Analg
2008
;
106
:
1487
90
10.
Hanci
V
,
Yurtlu
S
,
Ayoglu
H
,
Okyay
RD
,
Erdogan
G
,
Abdusoglu
M
,
Sayin
E
,
Turan
IO
:
Effect of low-flow anesthesia education on knowledge, attitude and behavior of the anesthesia team.
Kaohsiung J Med Sci
2010
;
26
:
415
21
11.
Kennedy
R
,
French
R
:
An audit of anaesthetic fresh-gas flow rates and volatile anaesthetic use in a teaching hospital.
N Z Med J
2003
;
116
:
U438
12.
Cherian
A
,
Badhe
A
:
Low-flow anaesthesia at a fixed flow rate.
Acta Anaesthesiol Scand
2009
;
53
:
1348
53
13.
Body
SC
,
Fanikos
J
,
DePeiro
D
,
Philip
JH
,
Segal
BS
:
Individualized feedback of volatile agent use reduces fresh gas flow rate, but fails to favorably affect agent choice.
Anesthesiology
1999
;
90
:
1171
5
14.
Berman
MF
,
Simon
AE
:
The effect of a drug and supply cost feedback system on the use of intraoperative resources by anesthesiologists.
Anesth Analg
1998
;
86
:
510
5
15.
Lubarsky
DA
,
Glass
PS
,
Ginsberg
B
,
Dear
GL
,
Dentz
ME
,
Gan
TJ
,
Sanderson
IC
,
Mythen
MG
,
Dufore
S
,
Pressley
CC
,
Gilbert
WC
,
White
WD
,
Alexander
ML
,
Coleman
RL
,
Rogers
M
,
Reves
JG
;
The successful implementation of pharmaceutical practice guidelines
:
Analysis of associated outcomes and cost savings. SWiPE Group. Systematic Withdrawal of Perioperative Expenses.
Anesthesiology
1997
;
86
:
1145
60
16.
Nair
BG
,
Newman
SF
,
Peterson
GN
,
Wu
WY
,
Schwid
HA
:
Feedback mechanisms including real-time electronic alerts to achieve near 100% timely prophylactic antibiotic administration in surgical cases.
Anesth Analg
2010
;
111
:
1293
300
17.
Nair
BG
,
Newman
SF
,
Peterson
GN
,
Schwid
HA
:
Automated electronic reminders to improve redosing of antibiotics during surgical cases: Comparison of two approaches.
Surg Infect (Larchmt)
2011
;
12
:
57
63
18.
Cleveland
WS
,
Grosse
E
,
Shyun
WM
:
Local regression Models, Statistical Models in S
. Edited by
Chambers
JM
,
Hastie
TJ
.
Edited by New York
,
Chapman & Hall Publishers
,
1993
, pp
pp 309
76
19.
Sandberg
WS
,
Sandberg
EH
,
Seim
AR
,
Anupama
S
,
Ehrenfeld
JM
,
Spring
SF
,
Walsh
JL
:
Real-time checking of electronic anesthesia records for documentation errors and automatically text messaging clinicians improves quality of documentation.
Anesth Analg
2008
;
106
:
192
201
20.
Kheterpal
S
,
Gupta
R
,
Blum
JM
,
Tremper
KK
,
O’Reilly
M
,
Kazanjian
PE
:
Electronic reminders improve procedure documentation compliance and professional fee reimbursement.
Anesth Analg
2007
;
104
:
592
7
21.
Spring
SF
,
Sandberg
WS
,
Anupama
S
,
Walsh
JL
,
Driscoll
WD
,
Raines
DE
:
Automated documentation error detection and notification improves anesthesia billing performance.
Anesthesiology
2007
;
106
:
157
63
22.
Wax
DB
,
Beilin
Y
,
Levin
M
,
Chadha
N
,
Krol
M
,
Reich
DL
:
The effect of an interactive visual reminder in an anesthesia information management system on timeliness of prophylactic antibiotic administration.
Anesth Analg
2007
;
104
:
1462
6
23.
St Jacques
P
,
Sanders
N
,
Patel
N
,
Talbot
TR
,
Deshpande
JK
,
Higgins
M
:
Improving timely surgical antibiotic prophylaxis redosing administration using computerized record prompts.
Surg Infect (Larchmt)
2005
;
6
:
215
21
24.
Prielipp
RC
:
An anesthesiologist’s perspective on inhaled anesthesia decision-making.
Am J Health Syst Pharm
2010
;
67
(
8 Suppl 4
):
S13
20
25.
Conzen
PF
,
Kharasch
ED
,
Czerner
SF
,
Artru
AA
,
Reichle
FM
,
Michalowski
P
,
Rooke
GA
,
Weiss
BM
,
Ebert
TJ
:
Low-flow sevoflurane compared with low-flow isoflurane anesthesia in patients with stable renal insufficiency.
Anesthesiology
2002
;
97
:
578
84
26.
Feldman
JM
:
Managing fresh gas flow to reduce environmental contamination.
Anesth Analg
2012
;
114
:
1093
101