Background

Obesity is an important risk factor for surgical site infections. The incidence of surgical wound infections is directly related to tissue perfusion and oxygenation. Fat tissue mass expands without a concomitant increase in blood flow per cell, which might result in a relative hypoperfusion with decreased tissue oxygenation. Consequently, the authors tested the hypotheses that perioperative tissue oxygen tension is reduced in obese surgical patients. Furthermore, they compared the effect of supplemental oxygen administration on tissue oxygenation in obese and nonobese patients.

Methods

Forty-six patients undergoing major abdominal surgery were assigned to one of two groups according to their body mass index: body mass index less than 30 kg/m2 (nonobese) or 30 kg/m2 or greater (obese). Intraoperative oxygen administration was adjusted to arterial oxygen tensions of approximately 150 mmHg and approximately 300 mmHg in random order. Anesthesia technique and perioperative fluid management were standardized. Subcutaneous tissue oxygen tension was measured with a polarographic electrode positioned within a subcutaneous tonometer in the lateral upper arm during surgery, in the recovery room, and on the first postoperative day. Postoperative tissue oxygen was also measured adjacent to the wound. Data were compared with unpaired two-tailed t tests and Wilcoxon rank sum test; P < 0.05 was considered statistically significant.

Results

Intraoperative subcutaneous tissue oxygen tension was significantly less in the obese patients at baseline (36 vs. 57 mmHg; P = 0.002) and with supplemental oxygen administration (47 vs. 76 mmHg; P = 0.014). Immediate postoperative tissue oxygen tension was also significantly less in subcutaneous tissue of the upper arm (43 vs. 54 mmHg; P = 0.011) as well as near the incision (42 vs. 62 mmHg; P = 0.012) in obese patients. In contrast, tissue oxygen tension was comparable in each group on the first postoperative morning.

Conclusion

Wound and tissue hypoxia were common in obese patients in the perioperative period and most pronounced during surgery. Even with supplemental oxygen tissue, oxygen tension in obese patients was reduced to levels that are associated with a substantial increase in infection risk.

OXIDATIVE killing by neutrophils is the primary defense against surgical pathogens, 1and the risk of infection is thus inversely related to tissue oxygen partial pressure. 2–4Tissue oxygenation is especially important in the hours immediately after bacterial contamination when infections are established; this time is known as the decisive period . 5Factors that reduce tissue oxygenation thus augment infection risk. 6For example, hypothermia and smoking—each of which reduces subcutaneous oxygen tension (Psqo2) 7,8—increase the incidence of infection. 9–11Obesity is also a major risk factor for surgical site infection and contributes to high morbidity and mortality in the obese population. 12,13 

Cardiac output, circulating blood volume, and resting oxygen consumption are all increased in obese persons 14; however, total blood flow is subnormal in relation to body weight. 15Obesity augments the size of individual fat cells without increasing blood flow. 16Fat tissue is therefore relatively hypoperfused 17and likely to be poorly oxygenated. Even supplemental oxygen fails to increase tissue oxygenation in hypoperfused tissues. 18Therefore, we tested the hypothesis that subcutaneous tissue oxygenation is inadequate in obese surgical patients and only minimally improved by administration of supplemental oxygen.

With approval from the Institutional Review Board at Washington University in St. Louis and written informed consent, we studied 46 patients aged 18–60 yr undergoing elective major abdominal surgery involving a midline abdominal incision. Exclusion criteria included documented coronary or peripheral artery disease, insulin-dependent diabetes mellitus, recent history of smoking, and any symptoms of infection or sepsis. We also excluded patients with preoperative systolic arterial blood pressure greater than 170 mmHg or diastolic arterial blood pressure greater than 90 mmHg.

Protocol

On the basis of their calculated body mass index (BMI; weight/height2), patients were assigned in advance to two groups: BMI less than 30 kg/m2(nonobese) or 30 kg/m2or greater (obese). 19Every patient was evaluated at two different intraoperative arterial oxygen partial pressure (Pao2) values: approximately 150 mmHg and approximately 300 mmHg. The treatment order was randomly assigned, based on computer-generated codes that were maintained in sequentially numbered opaque envelopes. The inspiratory oxygen fraction was adjusted in all patients to reach target partial pressures, which were maintained for 1 h.

General anesthesia was induced with sodium thiopental (3–5 mg/kg) and fentanyl (1–3 μg/kg). Vecuronium (0.1 mg/kg) or succinylcholine (0.8–1 mg/kg) was given to facilitate tracheal intubation. Ventilation was mechanically controlled to maintain arterial carbon dioxide partial pressure (Paco2) at approximately 40 mmHg. Positive end-expiratory pressure was maintained at 5 mmH2O, and peak ventilatory pressure was kept less than 30 mmH2O. Subsequently, anesthesia was maintained with sevoflurane (1–2%) in oxygen and air. Sevoflurane administration was adjusted to maintain mean arterial blood pressure within 20% of the preinduction value. A supplemental bolus dose of fentanyl (100 μg) was given when heart rate or arterial pressure increased more than 20% of the baseline value. No vasoactive drugs were given.

After induction of anesthesia, a 20-gauge cannula was inserted into a radial artery. In all patients, normal body weight in kilograms was calculated according to an average normal BMI of 22.5 kg/m2. A fluid bolus of 10 ml/kg normal body weight was given before induction of anesthesia. Subsequently, patients were given a maintenance dose of 10 ml/kg estimated normal body weight each hour. In addition, blood loss was replaced with crystalloid at a 4:1 ratio or colloid at a 2:1 ratio; supplemental fluid was given as necessary to maintain urine output greater than 1 ml/kg estimated normal body weight per hour. Allogenic blood was administered as necessary to maintain a hematocrit greater than 26%. Lower-body forced-air warming was used to keep patients normothermic.

At the end of surgery, wounds were dressed with standard surgical bandages that did not apply direct pressure to the wound. Anesthesia was discontinued, and the patients’ tracheas were extubated. Oxygen was delivered via  a facemask at a rate sufficient to maintain a Pao2of approximately 120 mmHg.

Postoperative pain was treated with intravenous morphine via  a patient-controlled analgesia system. Supplemental morphine was given as necessary by nurses who were not involved in the study and were not informed of the study purpose. In the PACU, crystalloid was administered at a rate of 3.5 ml/kg estimated normal body weight per hour. Additional fluid was given as necessary to maintain a urine output of at least 1 ml/kg estimated normal body weight per hour and a mean arterial blood pressure within 20% of the baseline value. Fluid management, supplemental oxygen administration, and analgesia on the ward were managed by the surgical team.

Measurements

Demographic data, American Society of Anesthesiologists physical status, preoperative laboratory values, and type and duration of surgery were recorded. All routine anesthetic, respiratory, and hemodynamic variables were also recorded. Detailed records of fluid management, including urine output, were kept. Inspired oxygen, end-tidal sevoflurane, and carbon dioxide concentrations were measured during anesthesia. Oxygen saturation was measured with pulse oximeters during anesthesia and postoperative measurement periods. Intraoperative core temperature was measured in the distal esophagus (Mon-a-therm; Tyco-Mallinckrodt Anesthesiology Products, St. Louis, MO). Postoperative core temperatures were measured with tympanic membrane probes (Mon-a-therm).

Arterial pressure was monitored continuously from the arterial catheter during surgery and in the PACU; it was measured noninvasively on the first postoperative morning. Because the primary determinants of tissue oxygen availability are arterial oxygen tension, cardiac output, and local perfusion, cardiac output was measured noninvasively using the partial rebreathing Fick method (NICO; Novametrix Medical System Inc., Wallingford, CT). Arterial blood gases were obtained intraoperatively and in the PACU as necessary to maintain the target arterial oxygen pressure.

After induction of anesthesia, a silastic tonometer was inserted into the lateral left upper arm for measurement of subcutaneous tissue oxygenation and temperature. At the end of surgery, a second tonometer was inserted 2–3 cm lateral and parallel to the surgical incision. Each tonometer consisted of 15 cm of tubing filled with hypoxic saline; 10 cm of the tubing was tunneled subcutaneously. A Clark-type oxygen sensor and thermistor (Licox; Gesellschaft für Medizinische Sondensysteme, GmBH, Kiel, Germany) were inserted into the subcutaneous portion of both tonometers as previously described. 20 

The in vitro  accuracy of the oxygen sensors is ± 3 mmHg for the range from 0 to 100 mmHg and ± 5% for 100 to 360 mmHg (in a water bath at 37°C). Temperature sensitivity is 0.25%/°C; thermistors are incorporated into the probes, and temperature compensation is included in the Psqo2calculations. Oxygen sensor calibration remains stable (within 8% of the baseline value for room air) in vivo  for at least 8 h. The electrodes are individually factory calibrated, but calibration was confirmed by exposing the electrode to room air (ambient partial pressure of oxygen [Po2] of 154 mmHg); in all cases, measurements in air were within 10% of 154 mmHg. To exclude a significant drift of the oxygen sensor, probes were again exposed to room air after each investigation; none differed by more than 10% from baseline values.

Subcutaneous oxygen tension was recorded in 10-min intervals during a 30-min measurement period following a 30-min equilibration period after reaching target Pao2values. Intraoperative Psqo2was recorded from the upper arm at arterial oxygen partial pressures of 150 and 300 mmHg. Postoperative Psqo2was recorded from the upper arm and adjacent to the surgical incision. Again, an equilibration period of 30 min was allowed before measurements were performed for 30 more minutes. On the first postoperative morning, baseline values were obtained from each site, with the patient breathing room air or sufficient supplemental oxygen to maintain an arterial saturation of at least 96%. Subsequently, measurements were repeated during oxygen challenge, which consisted of oxygen given at a rate of 10 l/min into a nonrebreathing facemask that provided an inspired oxygen fraction near 50%.

Data Analysis

Routine anesthetic measurements were recorded at 10-min intervals. The values were first averaged within each patient over each treatment condition (e.g. , measurement period); these values were subsequently averaged among the patients in each group. Routine postoperative values were evaluated similarly. Tissue oxygenation and related values were recorded at 10-min intervals during each measurement period. Measurements were first averaged within each patient over the relevant period; these values were subsequently averaged among the patients receiving each treatment.

Potential confounding factors and outcomes of the study were analyzed with unpaired, two-sided t  tests when the data were normally distributed. These results are presented as mean ± SD. Data that were not normally distributed were compared using the Wilcoxon rank sum test. These results are reported as median (25th percentile, 75th percentile). For paired comparisons, either a two-sided, paired t  test or a Wilcoxon signed-rank test was used. Once again, the test used depended on the distribution of the data values. P < 0.05 was considered statistically significant.

Age and height were similar in the two weight groups; there were significant differences in weight (70 ± 14 vs.  144 ± 45 kg), BMI (24 ± 4 vs.  51 ± 15 kg/m2), and American Society of Anesthesiologists physical status classification. There were also more women in the obese group than in the nonobese group. The duration of surgery was significantly longer for the obese patients (table 1). Nearly all of the obese patients had gastric bypass surgery; among the 23 others, 17 patients underwent colorectal surgery, and 6 had gastrectomies.

Table 1. Demographics and Morphometric Characteristics

Table 1. Demographics and Morphometric Characteristics
Table 1. Demographics and Morphometric Characteristics

Intraoperative Period

Anesthetic management, fluid replacement, urine output, blood loss, and core temperatures were similar at each oxygen concentration (table 2). Hemodynamic values were also comparable.

Table 2. Intraoperative Management

Table 2. Intraoperative Management
Table 2. Intraoperative Management

To achieve an arterial oxygen tension of approximately 150 mmHg, the obese patients required a fraction of inspired oxygen (Fio2) of 51 ± 18%, whereas the nonobese patients only needed 36 ± 5% (P < 0.001). The obese patients also needed a greater inspired oxygen concentration to reach an arterial oxygen tension of approximately 300 mmHg: 95 ± 5 versus  82 ± 11% (P < 0.001). Pao2and Paco2were comparable in each weight group within each designated oxygen treatment.

Subcutaneous oxygen tension was significantly less in the obese patients at an arterial oxygen tension near 150 mmHg: 36 versus  57 mmHg (P = 0.002). Psqo2was also significantly less in the obese patients at an arterial oxygen tension near 300 mmHg: 47 versus  76 mmHg (P = 0.014). Therefore, supplemental oxygen increased Psco2by 24 ± 34 mmHg in the nonobese patients but by only 13 ± 18 mmHg in the obese patients (P = 0.18;table 3and figs. 1–3).

Table 3. Intraoperative Hemodynamics, Respiratory Parameters, and Tissue Oxygenation

Table 3. Intraoperative Hemodynamics, Respiratory Parameters, and Tissue Oxygenation
Table 3. Intraoperative Hemodynamics, Respiratory Parameters, and Tissue Oxygenation

Fig. 1. Intraoperative tissue oxygen tensions during both oxygen conditions in individual obese patients. Group means and 95% confidence intervals are shown to the side. Pao2= arterial oxygen partial pressure; Psqo2= subcutaneous oxygen tension.

Fig. 1. Intraoperative tissue oxygen tensions during both oxygen conditions in individual obese patients. Group means and 95% confidence intervals are shown to the side. Pao2= arterial oxygen partial pressure; Psqo2= subcutaneous oxygen tension.

Close modal

Fig. 2. Intraoperative tissue oxygen tensions during both oxygen conditions in individual nonobese patients. Group means and 95% confidence intervals are shown to the side. Pao2= arterial oxygen partial pressure; Psqo2= subcutaneous oxygen tension.

Fig. 2. Intraoperative tissue oxygen tensions during both oxygen conditions in individual nonobese patients. Group means and 95% confidence intervals are shown to the side. Pao2= arterial oxygen partial pressure; Psqo2= subcutaneous oxygen tension.

Close modal

Fig. 3. Intraoperative tissue oxygen tensions during both oxygen conditions in individual obese and nonobese patients. Both horizontal  and vertical error bars  represent interquartile ranges. Pao2= arterial oxygen partial pressure; Psqo2= subcutaneous oxygen tension.

Fig. 3. Intraoperative tissue oxygen tensions during both oxygen conditions in individual obese and nonobese patients. Both horizontal  and vertical error bars  represent interquartile ranges. Pao2= arterial oxygen partial pressure; Psqo2= subcutaneous oxygen tension.

Close modal

PACU

Two obese patients could not be studied in the postoperative period because they required postoperative mechanical ventilation. Therefore, we evaluated 21 obese and 23 nonobese patients in the PACU. Mean arterial blood pressure, core temperature, fluid management, urinary output, and visual analog scale pain scores were comparable in the groups (table 4).

Table 4. PACU Management

Table 4. PACU Management
Table 4. PACU Management

Subcutaneous oxygen tension in the arm (43 vs.  54 mmHg; P = 0.01) and adjacent to the wound (42 vs.  62 mmHg; P = 0.01) was significantly less in obese than in the nonobese patients. However, within each weight group, tissue oxygen tensions measured at the arm and wound were virtually identical (table 5).

Table 5. PACU Tissue Oxygenation

Table 5. PACU Tissue Oxygenation
Table 5. PACU Tissue Oxygenation

First Postoperative Day

In two nonobese patients, measurements could not be performed because the patients withdrew from the study. Therefore, we evaluated 21 obese and 21 nonobese patients on the first postoperative morning. Mean arterial pressure and pain were similar in the two groups; however, urine output was significantly less and core temperature was greater in the obese patients (table 6).

Table 6. Postoperative Management on the First Postoperative Morning

Table 6. Postoperative Management on the First Postoperative Morning
Table 6. Postoperative Management on the First Postoperative Morning

Subcutaneous oxygen tensions in the arm as well as adjacent to the wound were similar in the obese and nonobese patients at baseline and during oxygen challenge. Supplemental oxygen significantly increased tissue oxygenation, by 14.4 (2.5, 26.9) mmHg in the obese patients and by 21.4 (14.4, 29.8) mmHg in the nonobese patients (P = 0.21). Within each weight group, Psco2values were virtually identical at the arm and the wound (table 7).

Table 7. Tissue Oxygenation on the First Postoperative Morning

Table 7. Tissue Oxygenation on the First Postoperative Morning
Table 7. Tissue Oxygenation on the First Postoperative Morning

Administration of 50% inspired oxygen to the obese patients, a typical concentration, produced a Pao2of 150 mmHg and an oxygen saturation of 99%. Intraoperative and immediate postoperative subcutaneous tissue oxygenation was nonetheless critically low (approximately 40 mmHg), a value associated with a high risk of infection. In contrast, tissue oxygenation in the nonobese patients was roughly 20 mmHg greater, a value that is considerably less likely to be associated with infection. 2Therefore, it is apparent that subcutaneous tissue is often hypoxic in obese patients undergoing routine anesthetic management. Although we did not evaluate the incidence of infection in this relatively small study, the link between subcutaneous oxygenation and wound infection risk is well established. Inadequate subcutaneous oxygenation is likely to account for the observed increased number of postoperative infections in obese patients. 12 

An inspired oxygen concentration of 95% was required to increase Pao2to 300 mmHg in the obese patients. However, this 150-mmHg increase in arterial partial pressure improved subcutaneous oxygenation only 10 mmHg—to a value that remained marginal. Medical oxygen is possibly the least expensive drug, and supplemental intraoperative oxygen is easy to provide. Prolonged administration of oxygen at concentrations near 100% causes pulmonary toxicity. 21,22However, short-term exposure in the perioperative period is nontoxic and may even improve pulmonary resistance to infection. 23Perioperative concentrations of oxygen restricted to 80% do not provoke atelectasis or other pulmonary dysfunction. 24Therefore, available data suggest that it would be prudent to provide obese patients with an inspired oxygen concentration of at least 80% because the risk and cost are small, and doing so somewhat improves tissue oxygenation.

Supplemental oxygen administration is one of many factors influencing Psco2. For example, it is well established that hypothermia, 7surgical and postoperative pain, 25,26and smoking 8all reduce tissue oxygen tension. In contrast, administration of supplemental fluid, 27hypercapnia, 28and epidural anesthesia 26,29increase subcutaneous tissue oxygenation. Intraoperative tissue oxygenation was suboptimal in our obese patients, at a Pao2of 150 mmHg, and remained marginal even with an inspired oxygen concentration of 95%. Therefore, it is likely that combining supplemental oxygen with other treatments that have a potential of improving tissue oxygenation may prove beneficial in obese patients.

Interestingly, arm and wound tissue oxygen tensions were comparable in obese and nonobese patients on the first postoperative day. Furthermore, supplemental oxygen administration was considerably more effective postoperatively in the obese patients than intraoperatively (approximately 20 vs.  10 mmHg)—although delivery of oxygen (via  a facemask) was surely less effective. A potential explanation for this different response is that the obese patients had significantly higher core temperatures. Hyperthermia causes peripheral vasodilation, hyperemia, and increased tissue perfusion. 30Furthermore, it is likely that obese patients are fairly hypercapnic in the postoperative period; mild hypercapnia is known to improve tissue oxygenation. 28 

Intraoperatively, we recorded Psco2from a needle-induced surrogate wound in the arm. This is the classic method of evaluating perioperative tissue oxygenation and has been used in numerous previous studies. 6,25,28The primary benefit of this location is convenient access and the fact that measurements can be conducted during surgery. However, the tissue of interest is actually the surgical incision. Therefore, we simultaneously recorded tissue oxygenation adjacent to the surgical incision postoperatively. The results were encouraging in that average values at each site were virtually identical. Similar arm and wound partial pressures are consistent with the single previous direct clinical comparison by Chang et al. , 31who reported that measurements in the chest wound are only approximately 10 mmHg less than in the arm. However, in that study, Psco2measurements were performed directly in a mastectomy wound, whereas our values were recorded from surrogate wounds adjacent to the surgical incision. Chang et al.  did not measure subcutaneous tissue temperature, whereas our Psco2values are temperature corrected. This is of importance because subcutaneous tissue temperature was greater in the wound than in the arm under all conditions, presumably as a result of inflammation and erythema. Taken together, these results suggest that values recorded from the arm are reliable substitutes for less convenient measurements from surgical wounds.

The observed tissue oxygen values in our study were slightly less than in previous studies, even in the nonobese patients. 6This may be explained by the fact that our patients were randomly assigned to two oxygen treatments. Consequently, in 50% of all patients, the high oxygen condition was initiated at a point during anesthesia and surgery when peripheral tissue perfusion might have already been compromised because of sympathoadrenergic stimulation and relative hypovolemia.

Naturally, it was impossible to assign patients randomly to the two weight groups. A consequence is that there were more women in the obese group than the nonobese group. Currently, there are no convincing data available that sex per se  might be a confounding factor of tissue oxygenation and perfusion. Nevertheless, some endocrinologic influence cannot be excluded. For example, 17β-estradiol is a vasodilator and increases cardiac output.

The two primary determinants of subcutaneous oxygenation are Pao2and tissue perfusion, both of which depend critically on anesthetic and fluid management. Therefore, fluid management was strictly controlled by protocol, using estimated normal body weight as the basis for management. However, there is no consensus on what constitutes optimal or even comparable fluid management in obese patients. 32It is therefore possible that this conservative regimen made our obese patients relatively hypovolemic. Nonetheless, hemodynamic parameters, such as mean arterial blood pressure and cardiac index, were similar in both groups, as was urine output. These data suggest that our perioperative fluid administration was adequate even in the obese patients.

Surgery lasted significantly longer in the obese than in the nonobese patients. However, intraoperative tissue oxygen was recorded at similar times, usually during the first 2 h of surgery in each weight group. Therefore, it seems unlikely that observed intraoperative differences between the obese and nonobese patients were artifacts of anesthetic or fluid management. There is evidence that duration of surgery is a confounding factor in regard to postoperative tissue oxygen tension 2; we cannot exclude that duration of surgery affected our Psco2values in the postoperative period. However, all patients underwent major abdominal procedures with similar surgical stress responses and pathophysiologic alterations. 31 

It seems likely that preoperative tissue oxygenation differed substantially in the obese and nonobese patients. However, we cannot confirm this assertion because our recording began after induction of general anesthesia. The primary reason we delayed data collection was that unanesthetized patients find probe insertion uncomfortable. Furthermore, measurements during baseline conditions in uninjured tissues before initiation of surgical trauma and bacterial contamination are of less clinical impact. Therefore, we considered only intraoperative and postoperative measurements to be of major importance.

In summary, our data indicate that obesity, defined as a BMI of 30 kg/m2or greater, is a major determinant of perioperative tissue oxygenation. In obese surgical patients, subcutaneous tissue hypoxia was common. Even with supplemental oxygen administration, tissue oxygen tension was reduced to a level that is associated with a substantial increase in infection risk. Tissue oxygenation recorded from a surrogate wound in the arm was similar to that recorded from a probe inserted adjacent to the surgical incision, suggesting that the technically simpler arm measurements can be substituted for more challenging wound recordings.

1.
Babior BM: Oxygen-dependent microbial killing by phagocytes. N Engl J Med 1978; 298: 659–68
2.
Hopf HW, Hunt TK, West JM, Blomquist P, Goodson WH III, Jensen JA, Jonsson K, Paty PB, Rabkin JM, Upton RA, von Smitten K, Whitney JD: Wound tissue oxygen tension predicts the risk of wound infection in surgical patients. Arch Surg 1997; 132: 997–1004
3.
Gottrup F: Physiology and measurement of tissue perfusion. Ann Chir Gynaecol 1994; 83: 183–9
4.
Van Esbroeck G, Gys T, Hubens A: Evaluation of tissue oximetry in perioperative monitoring of colorectal surgery. Br J Surg 1992; 79: 584–7
5.
Miles AA, Miles EM, Burke JP: The value and duration of defense reactions of the skin to the primary lodgement of bacteria. Br J Exp Pathol 1957; 38: 79
6.
Greif R, Akca O, Horn EP, Kurz A, Sessler DI: Supplemental perioperative oxygen to reduce the incidence of surgical-wound infection. Outcomes Research Group. N Engl J Med 2000; 342: 161–7
7.
Sheffield CW, Sessler DI, Hopf HW, Schroeder M, Moayeri A, Hunt TK, West JM: Centrally and locally mediated thermoregulatory responses alter subcutaneous oxygen tension. Wound Rep Reg 1997; 4: 339–45
8.
Jensen JA, Goodson WH, Hopf HW, Hunt TK: Cigarette smoking decreases tissue oxygen. Arch Surg 1991; 126: 1131–4
9.
Kurz A, Sessler DI, Lenhardt R: Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. Study of Wound Infection and Temperature Group. N Engl J Med 1996; 334: 1209–15
10.
Stopinski J, Staib I, Weissbach M:[Do abuse of nicotine and alcohol have an effect on the incidence of postoperative bacterial infections]? J Chir (Paris) 1993; 130: 422–5
11.
Melling AC, Ali B, Scott EM, Leaper DJ: Effects of preoperative warming on the incidence of wound infection after clean surgery: A randomised controlled trial. Lancet 2001; 358: 876–80
12.
Choban PS, Heckler R, Burge JC, Flancbaum L: Increased incidence of nosocomial infections in obese surgical patients. Am Surg 1995; 61: 1001–5
13.
Moulton MJ, Creswell LL, Mackey ME, Cox JL, Rosenbloom M: Obesity is not a risk factor for significant adverse outcomes after cardiac surgery. Circulation 1996; 94: II87–92
14.
de Divitiis O, Fazio S, Petitto M, Maddalena G, Contaldo F, Mancini M: Obesity and cardiac function. Circulation 1981; 64: 477–82
15.
Cheymol G: Drug pharmacokinetics in the obese. Fundam Clin Pharmacol 1988; 2: 239–56
16.
Jansson PA, Larsson A, Smith U, Lonnroth P: Glycerol production in subcutaneous adipose tissue in lean and obese humans. J Clin Invest 1992; 89: 1610–7
17.
Di Girolamo M, Skinner NS Jr, Hanley HG, Sachs RG: Relationship of adipose tissue blood flow to fat cell size and number. Am J Physiol 1971; 220: 932–7
18.
Jonsson K, Jensen JA, Goodson WH III, West JM, Hunt TK: Assessment of perfusion in postoperative patients using tissue oxygen measurements. Br J Surg 1987; 74: 263–7
19.
National Heart, Lung and Blood Institute Obesity Education Initiative Expert Panel: Clinical Guidelines on the Identification, Evaluation, and Treatment of Overweight and Obesity in Adults. Bethesda, National Institutes of Health, 1998
20.
Hopf HW, Viele M, Watson JJ, Feiner J, Weiskopf R, Hunt TK, Noorani M, Yeap H, Ho R, Toy P: Subcutaneous perfusion and oxygen during acute severe isovolemic hemodilution in healthy volunteers. Arch Surg 2000; 135: 1443–9
21.
de los Santos R, Seidenfeld JJ, Anzueto A, Collins JF, Coalson JJ, Johanson WG Jr, Peters JI: One hundred percent oxygen lung injury in adult baboons. Am Rev Respir Dis 1987; 136: 657–61
22.
Smith LJ: Hyperoxic lung injury: Biochemical, cellular, and morphologic characterization in the mouse. J Lab Clin Med 1985; 106: 269–78
23.
Kotani N, Hashimoto H, Sessler DI, Muraoka M, Hashiba E, Kubota T, Matsuki A: Supplemental intraoperative oxygen augments antimicrobial and proinflammatory responses of alveolar macrophages. A nesthesiology 2000; 93: 15–25
24.
Akca O, Podolsky A, Eisenhuber E, Panzer O, Hetz H, Lampl K, Lackner FX, Wittmann K, Grabenwoeger F, Kurz A, Schultz AM, Negishi C, Sessler DI: Comparable postoperative pulmonary atelectasis in patients given 30% or 80% oxygen during and 2 hours after colon resection. A nesthesiology 1999; 91: 991–8
25.
Akca O, Melischek M, Scheck T, Hellwagner K, Arkilic CF, Kurz A, Kapral S, Heinz T, Lackner FX, Sessler DI: Postoperative pain and subcutaneous oxygen tension. Lancet 1999; 354: 41–2
26.
Buggy DJ, Doherty WL, Hart EM, Pallett EJ: Postoperative wound oxygen tension with epidural or intravenous analgesia: A prospective, randomized, single-blind clinical trial. A nesthesiology 2002; 97: 952–8
27.
Arkilic CF, Taguchi A, Sharma N, Ratnaraj J, Sessler DI, Read TE, Fleshman JW, Kurz A: Supplemental perioperative fluid administration increases tissue oxygen pressure. Surgery 2003; 133: 49–55
28.
Akca O, Doufas AG, Morioka N, Iscoe S, Fisher J, Sessler DI: Hypercapnia improves tissue oxygenation. A nesthesiology 2002; 97: 801–6
29.
Kabon B, Fleischmann E, Treschan T, Taguchi A, Kapral S, Kurz A: Thoracic epidural anesthesia increases tissue oxygenation during major abdominal surgery. Anesth Analog 2003; 97: 1812–7
30.
Sessler DI: Sweating threshold during isoflurane anesthesia in humans. Anesth Analg 1991; 73: 300–3
31.
Chang N, Goodson WH III, Gottrup F, Hunt TK: Direct measurement of wound and tissue oxygen tension in postoperative patients. Ann Surg 1983; 197: 470–8
32.
Waki M, Kral JG, Mazariegos M, Wang J, Pierson RN Jr, Heymsfield SB: Relative expansion of extracellular fluid in obese vs. nonobese women. Am J Physiol 1991; 261: E199–203