Background

Nonlinear electroencephalographic parameters, e.g., approximate entropy, have been suggested as measures of the hypnotic component of anesthesia. Compared with linear methods, they may detect additional information and quantify the irregularity of a dynamical system. High dimensionality of a signal and disturbances may affect these parameters and change their ability to distinguish consciousness from unconsciousness. Methods of order pattern analysis, in this investigation represented by permutation entropy, recurrence rate, and phase coupling of order recurrence plots, are suitable for any type of time series, whether deterministic or noisy. They may provide a better estimation of the hypnotic component of anesthesia than other nonlinear parameters.

Methods

The current analysis is based on electroencephalographic data from two similar clinical studies in adult patients undergoing general anesthesia with sevoflurane or propofol. The study period was from induction until patients followed command after surgery, including a reduction of the hypnotic agent after tracheal intubation until patients followed command. Prediction probability was calculated to assess the parameter's ability to separate consciousness from unconsciousness at the transition between both states.

Results

Parameters of order pattern analysis provide a prediction probability of maximal 0.85 (training study) and 0.78 (evaluation study) with frequencies from 0 to 30 Hz, and maximal 0.87 (training study) and 0.83 (evaluation study) including frequencies up to 70 Hz, both higher than 0.77 (approximate entropy).

Conclusions

Parameters of the nonlinear method order pattern analysis separate consciousness from unconsciousness and are grossly independent of high-frequency components of the electroencephalogram.

ELECTROENCEPHALOGRAM-BASED monitors have obtained increasing interest as a supplement to standard anesthesia monitoring with the aim of reducing the risk of awareness. The electroencephalogram is based on the electrical activity of the brain, which is picked up by scalp electrodes. Electroencephalographic signals can be understood as a superposition of postsynaptic potentials mainly generated in layer V of the cerebral cortex, an ultrahigh-dimensional dynamical system.1The main objective of electroencephalogram-based parameters is a reduction of the complex electroencephalographic pattern to a single value that is associated with the anesthetic drug effect and clinical patient status, e.g. , consciousness and unconsciousness.2 

Different methods have been applied to electroencephalographic signal analysis.1,3Parameters based on the frequency spectrum reflect only linear signal properties, where median frequency3and spectral edge frequency3are well-known examples and have been recently improved by the introduction of weighted spectral median frequency.4It has been shown that a restriction of the classic electroencephalographic frequency band (0–30 Hz) using a high-pass filter at 8 Hz and an attenuation of high spectral amplitudes results in a parameter that separates consciousness from unconsciousness.4This approach reflects only linear properties of the electroencephalogram and omits frequencies below 8 Hz, which may limit parameter performance over the entire range of anesthesia.

Nonlinear electroencephalographic parameters, e.g. , correlation dimension5,6and Lempel Ziv complexity,7as well as entropies8such as approximate entropy (ApEn),9,10may emphasize some additional characteristics of the electroencephalogram that are related to nonlinear systems or may be used to model the electrical activity of the brain.1,8,11A main problem of most complexity measures such as correlation dimension in analysis of the electroencephalogram is that some requirements for the signal quality are not met, so reliable estimates may not be obtained.1,12For example, most such parameters require a sufficient number of data points for calculation, which are not available because the electroencephalogram may not be stationary for time periods longer than a few seconds. ApEn was designed to overcome these restrictions to some extent,10and therefore it is included in the current analysis. It has been shown that ApEn can be used to indicate deepening of anesthesia until electroencephalographic burst suppression.10,13,14Permutation entropy (PeEn)15is a recently introduced method for analyzing time series in general, i.e. , without constraints to their generation process. Therefore, PeEn should be adequate to analyze electroencephalographic signals that are high dimensional and superposed with artifacts, even if the signal length is limited.16,17Both recurrence rate and phase coupling of order recurrence plots (ORR and OPC)18can be considered as similar to PeEn. The parameters ApEn, PeEn, ORR, and OPC are assessed using electroencephalographic data at the transition from consciousness to unconsciousness (or vice versa ). For parameter calculation, different high cutoff frequencies were considered. This indicates how much a parameter may depend on the presence of high-frequency components (> 30 Hz) to distinguish consciousness from unconsciousness. Inclusion of high frequencies bears the risk that such components do not only reflect the electrical cortical activity, but are influenced or generated by the electromyogram, affecting the detection of potential awareness.

A central question is whether the application of nonlinear methods to the analysis of electroencephalographic signals yields information that cannot be obtained by conventional measures. A comparison of both approaches seems to be adequate, but only if the involved electroencephalographic parameters have been carefully adapted to the signal properties.

The aim of this study was to determine which characteristics of selected nonlinear parameters show greatest association with consciousness versus  unconsciousness. Responsiveness to command was used as a conservative measure of consciousness identifying patients who may soon become capable of formulating recall.2Data immediately before and after loss and return of consciousness from two previously studied cohorts were used for parameter calculation, one for parameter development and the other for parameter evaluation.

Protocol Design and Data Collection

Data from two clinical studies with similar clinical design were used for the current analysis and were denoted as study A and study B. Both studies were approved by the ethics committee of the Technische Universität München, Faculty of Medicine, Munich, Germany. In each of the studies, 40 consenting adult patients undergoing general anesthesia were enrolled,2,19and the study period was from induction of anesthesia until patients followed command after surgery and included a reduction of the hypnotic agent after tracheal intubation until patients followed command. Patients with contraindications to the study drugs, with a history of psychiatric or neurologic disease, drug abuse, or medication known to affect the central nervous system, pregnancy, or indication for rapid-sequence induction were excluded from the study. In study A, patients were randomly assigned to an anesthetic regimen with remifentanil (minimum infusion rate 0.2 μg · kg−1· min−1) and sevoflurane (20 patients) or remifentanil and propofol (20 patients).2,19In study B, the sevoflurane and propofol groups were divided into two subgroups with either “low” infusion rate of remifentanil (0.1 μg · kg−1· min−1) or “high” infusion rate (0.2 μg · kg−1· min−1).2,19Without premedication, remifentanil infusion was started via  a cannula in the cubital vein. In 30-s intervals, patients were asked to squeeze the investigator's hand. A response was verified by an immediate repetition of the command that also required a response. This prevents a misinterpretation of involuntary movement as a response. Anesthesia was slowly induced with sevoflurane inhalation or propofol injection (0.7 mg/kg, followed by 20 mg every 30 s). The first time when the patient did not squeeze the investigator's hand to command was labeled as loss of consciousness 1. Additional propofol or sevoflurane was given to increase depth of anesthesia, a tourniquet was used to occlude the circulation of the right forearm for 5 min to maintain the ability to move the hand to command, and then succinylcholine (1.0 mg/kg) was given (Tunstall isolated forearm technique).20After intubation, sevoflurane or propofol was stopped until patients followed command (return of consciousness 1). Thereafter, sevoflurane (5 vol%) or propofol (20-mg boluses) was readministered to induce anesthesia again. The time when patients stopped responding to command again was defined as loss of consciousness 2, and requests to squeeze the hand were stopped. Anesthetic drugs were administered according to clinical practice, and surgery was performed. At the end of surgery, requests to squeeze the hand were recommenced, and sevoflurane, propofol, and remifentanil were discontinued. Return of consciousness 2 was observed at the first verified response to command. Recovered from anesthesia, patients were asked for signs of recall in the recovery room. This interview21was repeated within 48 h in the ward. Standard monitoring parameters were measured with a Datex AS/3 (Datex-Ohmeda Division Instrumentation Corp., Helsinki, Finland) compact anesthesia monitor. For data transfer and storage, a personal computer with NeuMonD (Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, Munich, Germany) was used. NeuMonD is a software program developed by members of the research group allowing the recording of monitoring data and the electronic storage of events and comments during the study.22In addition to standard monitoring, the electroencephalogram and auditory evoked potentials were measured (study A). Two-channel electroencephalographic signals at electrode positions AT1, M2, Fpz (reference), and F7 (ground) were recorded on a second personal computer with synchronized system time. This auditory evoked potential/electroencephalographic device has been designed specifically for intraoperative use and has been described previously.23Electroencephalogram and concomitant trigger information of auditory evoked potentials were stored with a sampling rate of f  s= 1,000 Hz and 12-bit amplitude resolution. In study B, the electroencephalogram was recorded using the Aspect A-1000 electroencephalographic monitor (BIS® version 3.3; Aspect Medical Systems Inc., Newton, MA). A two-channel referential electroencephalogram was obtained from ZipPrep Ag/AgCl electrodes in positions AT1, AT2, Fz (reference), and Fp1 (ground, electrode positions according to the international 10-20 system). The high pass was set at 0.25 Hz, and the notch filter (50 Hz) was enabled. The electroencephalogram was continuously digitized at 256 Hz per channel and simultaneously recorded with standard monitoring parameters. For data analysis in both studies, a time window duration of T = 10 s was used.

Signal processing and statistical analysis were performed using LabVIEW 6.0 (National Instruments, Austin, TX), MATLAB 6.0 release 12 (The MathWorks, Inc., Natick, MA), and R 2.4.0 (R Foundation for Statistical Computing, Vienna, Austria) on personal computers with Windows XP (Microsoft Corporation, Redmond, WA).

Approximate Entropy

In 1991, Pincus et al.  proposed ApEn, which is related to Kolmogorov Sinai entropy and quantifies the irregularity in a signal.9,10Although “long” signals containing as many data points as possible are beneficial to analyze high-dimensional dynamical systems, this requirement cannot be fulfilled in the case of the electroencephalogram, e.g. , because of nonstationarity. ApEn should overcome this problem and allows a computation on the basis of signals with moderate length.10,24It gives a predictability of current amplitude values based on the knowledge of n  previous signal amplitudes, i.e. , n  is the length of compared runs of data (embedding dimension). The calculation of ApEn is based on a distance function applied to pairs of subvectors of length n , where a noise filter defines the tolerance r  that will discern “close” and “not close” subvectors of length n . It has been shown that n  and r  are in a way dependent on the available signal length N , where N > 10n  is recommended.9,10In the current investigation, ApEn is computed using n  between 2 and 15 (n  of 2 and 3 is recommended),10providing subvectors with a time span between 10 and 75 ms. A tolerance of r = 0.2 × SD of the analyzed electroencephalographic signal is chosen for parameter calculation. A time span of 10 s and f  s= 200 Hz implies a signal length of N = 2,000. Furthermore, parameter calculation is performed using the complete electroencephalographic frequency band from 0.5 Hz, with different high cutoff frequencies f  highfrom 30 to 70 Hz, i.e. , with or without the gamma band of the electroencephalogram. To avoid influences of the electromyogram (muscle activity), a high cutoff frequency of 30 Hz is of particular interest in the analysis (classic electroencephalographic frequency band).

In nonlinear signal analysis methods, as represented by ApEn, PeEn, OPC, and ORR, the embedding dimension n  is basically intended as one component to determine low-dimensional dynamics of the generating system. It may lead to information about the time evolution of the system state, especially whether a dynamical system shows determinism or is random. Unfortunately, a reliable estimation of n  is limited in the case of the electroencephalogram, because the signal is suspected to be ultrahigh-dimensional and may show characteristics similar to noise.25,26Even if the methods provide favorable results at specific values of the embedding dimension, conclusions regarding determinism and dimensionality of the electroencephalogram must be drawn with caution. Nevertheless, in the current analysis, varying the embedding dimension n  should indicate how much a parameter is sensitive to a specific value of n . Robustness may be advantageous because of the mostly unknown generating dynamics of the brain and because of a shift in predominant frequencies of the electroencephalogram with changing levels of anesthesia.

Permutation Entropy

Permutation entropy was introduced by Bandt et al.  15in 2002. Similarly to ApEn, PeEn is a measure of the irregularity of signals, and it is based on a comparison of the neighboring order of signal values. It has been shown that PeEn is mainly unaffected by signal disturbances, and it can be used to analyze time series generated by high-dimensional systems with low stationarity. Similar to ApEn, PeEn analyzes consecutive subvectors of constant length n  (embedding dimension) in the analyzed signal interval. The order of samples in every subvector according to their amplitudes is computed and defines permutations of order n . The parameter value is given by the entropy of the distribution of the obtained permutations and quantifies the monotone behavior of adjacent signal amplitudes. Therefore, PeEn remains independent of absolute amplitude values. A calculation example of PeEn is shown in figure 1. In the current analysis, the dimension n  varies between 2 and 15 (n  between 3 and 7 is recommended),15with a sampling rate corresponding to the frequency f  sof 200 Hz, so that analyzed subvectors include a time span between 10 and 75 ms. If n ! is high compared with the number of available samples in the signal, there is a bias in the calculation of PeEn, because the n ! possible permutations appear with unequal probabilities.15Different settings of the high cutoff frequency f  high(as for ApEn) and the embedding dimension n  may change the capability of PeEn to separate consciousness from unconsciousness.

Order Recurrence Rate and Order Phase Coupling

Recurrence plots detect dependencies in a dynamical system, i.e. , coupling properties at different time points of a time series or in multivariate data.27Related to the idea of PeEn, recurrence plots can be adapted in the language of order pattern analysis that may improve the robustness against amplitude distortions, as proposed by Groth.18Two measures in the context of order recurrence plots are applied in this investigation.

First, the ORR18is a measure of statistical similarities in time series, where the similarity is defined by comparing the order of amplitudes in two shifted subvectors of length n  (dimension) with respect to a fixed time lag of τ. For these purposes, ORR computes the number of similar pairs of subvectors in the signal. Similarity is defined as 1 when the order of both subvectors is equal; otherwise it is 0. Figure 2shows the calculation scheme of ORR based on an exemplary time series. In the current analysis, ORR is analyzed on the basis of a frequency range and embedding dimension n  as described for the parameter ApEn. For τ > 4, the ability to separate consciousness from unconsciousness decreases. In the analysis, τ between 1 and 10, i.e. , a time lag of 5–50 ms between each pair of subvectors, is considered (see Results). The time lag τ may indicate time related coupling effects in a signal generated by a (low-dimensional) dynamical system.25,26 

Second, the OPC18quantifies the degree of coupling over the time lag τ. It is defined as the Shannon entropy of a normalized ORR over τ, where the time lag τ varies from 1 to a fixed upper bound. Therefore, OPC is related to the calculation of ORR as shown in figure 2. In the current analysis, the frequency range and n  are applied as described for the parameter ApEn, and for the upper bound of τ, values from 3 to 10 are used, which allows calculation in an acceptable time frame.

Notice that the above is only a rough description of the mathematically sophisticated parameters ORR and OPC: PeEn, ORR, and OPC reflect similar properties when applied to electroencephalographic signals. Therefore, the main focus is on PeEn, a very understandable and expedient method for electroencephalographic analysis.

Parameter Assessment and Statistical Analysis

Parameter settings for the high cutoff frequency f  highand embedding dimension n  for the parameters ApEn, PeEn, ORR, and OPC are varied to identify settings that indicate changes from consciousness to unconsciousness (or vice versa ). This approach will indicate whether the parameters are dependent on signal information with frequencies above the classic electroencephalographic frequency band (f  high= 30 Hz) and may therefore include electromyographic information to detect consciousness.

Parameter calculation is based on a set of electroencephalographic signals (samples) of T = 10 s duration directly before or after the transition between consciousness and unconsciousness. Study A and study B each involved 40 patients.2,4,19Two signals were analyzed at each of the following clinical events: loss of consciousness 1 and 2 and return of consciousness 1 and 2. Therefore, a maximum of 320 signals was available from each study, A and B (see Protocol Design and Data Collection). The signals are entirely derived from either a phase of consciousness or a phase of unconsciousness. Automatic artifact detection was used to exclude signals of constant amplitude (“flat” line) or values exceeding the measuring range of 250 μV. For study A (development study), 279 signals (133 assigned to consciousness and 146 assigned to unconsciousness) were used for analysis, and for study B (evaluation study), 278 signals (125 assigned to consciousness and 153 assigned to unconsciousness) were used for analysis.

Results from prediction probability (P  K)28were used to identify suitable settings for the parameters ApEn, PeEn, ORR, and OPC. Data from study A were used to optimize parameter settings for the upper frequency limit. P  Kwas calculated for a frequency range of up to (1) 30 Hz, (2) 49 Hz, and (3) 70 Hz. For verification, identified settings were applied to data from study B to calculate P  Kfor the separation of consciousness from unconsciousness for ApEn, PeEn, ORR, and OPC.

Bootstrap confidence intervals29(1,000 resamples, significance level of 95%, Bonferroni correction for the comparison of four P  Ktest statistics)30were used to identify significant differences of P  Kvalues of selected parameters taken from study B.

Results of Study A (Development Study)

Figure 3shows P  Kvalues for the electroencephalographic parameters ApEn, PeEn, ORR, and OPC on the basis of electroencephalographic data from study A, where a P  Kvalue results for every mapped embedding dimension (n = 2, 3, …, 15) and high cutoff frequency (f  high= 30, 31, . . ., 70 Hz).

P  Kof ApEn (fig. 3A) depends on the choice of the high cutoff frequency f  high, e.g. , P  Kvalues vary between 0.60 and 0.76 using the recommended10embedding dimension of n = 2. A maximum P  Kvalue of 0.77 is obtained for the settings f  high= 70 Hz and n = 7.10 

Order pattern analysis reaches a maximum P  Kof 0.87 with settings as shown in table 1. Three groups of high cutoff frequencies are considered: (1) f  high= 30 Hz, (2)f  high≤ 49 Hz, and (3) f  high≤ 70 Hz. In contrast to ApEn with a maximum P  Kfor f  high= 70 Hz, PeEn, ORR, and OPC (figs. 3B–D) achieve maximal P  Kvalues within group 2 with f  high≤ 49 Hz. Furthermore, PeEn and ORR are grossly independent of the choice of the high cutoff frequency f  high, e.g. , P  Kof PeEn remains “stable” between 0.84 and 0.87 for the recommended embedding dimension of n = 5.15Therefore, order pattern analysis may neither be sensitive nor depend on the presence of high-frequency components in the electroencephalographic signal. Furthermore, P  Kof PeEn seems to remain stable if the embedding dimension n  is shifted over a wide range between 3 and 12 (P  Kbetween 0.81 and 0.87). The time lags τ= 2 for the parameter ORR and τ= 3 for OPC provide highest P  Kfor both parameters.

Exemplary Time Series

Figure 4A shows exemplar time series of the parameters ApEn (n = 2)10and PeEn (n = 5)15based on the full “classic” electroencephalographic frequency range from 0.5 to 30 Hz. In figure 4B, the plots of ApEn (f  high= 70 Hz, n = 7) and PeEn (f  high= 42 Hz, n = 9) using the settings with highest P  Kare shown, i.e. , including the electroencephalographic gamma band, which may contain electromyographic activity.

Although P  Kvalues of PeEn are mainly independent of f  high, the analysis of time series shows that the parameter values are more stable during wakefulness if high frequencies (above the classic electroencephalographic band) are included in the analysis. After loss of consciousness 1, PeEn and ApEn follow the hypnotic component of anesthesia. Before loss of consciousness 1, ApEn may be sensitive to signal disturbances, e.g. , generated by muscle artifacts.

Results of Study B (Validation Study)

Parameters with maximal P  Kvalues based on data from study A were validated using electroencephalographic data from study B. The resulting P  Kvalues are shown in table 1.

Order pattern measures PeEn and ORR lead to significantly higher P  Kthan ApEn for every group of high cutoff frequencies f  high, i.e. , (1) f  high= 30 Hz, (2) f  high≤ 49 Hz, and (3) f  high≤ 70 Hz. P  Kvalues of parameters based on a high cutoff frequency of f  high= 30 Hz are not significantly different from the P  Kof parameters including frequencies above 30 Hz.

Electroencephalogram-based monitoring of the hypnotic component of anesthesia should reliably indicate the level of consciousness and may reduce the risk of awareness in a patient population at high risk.31Analysis of the electroencephalogram requires mathematical techniques that reflect information of cortical activity of the brain, which can be seen as an ultrahigh-dimensional nonlinear dynamical system.1Such techniques should be as independent as possible from additional sources that may be superposed on the electroencephalogram, such as muscle activity.

In a traditional approach, harmonic analysis of the electroencephalogram is used. This may lead to acceptable results for the separation of consciousness from unconsciousness. A recently developed electroencephalographic parameter that follows these criteria is the weighted spectral median frequency.3,4,32Nevertheless, nonlinear measures may provide additional information about the signal.7,8,10,15,33The electroencephalographic parameters ApEn, PeEn, ORR, and OPC are such nonlinear methods. Each of these parameters has different requirements for the analyzed signal. ApEn analyzes differences of amplitudes, whereas PeEn, ORR, and OPC are based on the analysis of order patterns and analyze order of amplitudes—entirely independent of signal values. This can be advantageous if signals are highly nonstationary and superposed with noise,15as is the case with the intraoperatively recorded electroencephalogram. For example, fluctuations in electrode impedance may not essentially affect parameters of order pattern analysis. Previous studies have shown that PeEn, ORR, and OPC are robust against signal artifacts,15,18making the parameters suitable for electroencephalographic monitoring of anesthesia. In the current analysis, parameters were calculated from the electroencephalogram immediately before and after loss and return of consciousness, to assess their performance at a critical point, the transition between consciousness and unconsciousness. For the current analysis, consciousness was defined as responsiveness to command. This approach identifies intact short-term (working) memory, a memory of small capacity that holds a small amount of information in an active, available state for approximately 20 s and must not be confused with long-term memory (recall). Patients with intact short-term memory will not necessary remember that they were conscious. Nevertheless, intact short-term memory provides the basis for conscious perception and subsequent recall, i.e. , avoidance of intact short-term memory will prevent memory and recall.

For both study A and study B, patients were randomly assigned to receive either total intravenous anesthesia or a combination of opioid and volatile anesthetic. This was performed to include both anesthetic regimens equally into the data set for parameter development (study A) and validation (study B) and to avoid overfitting of a parameter to a specific anesthetic regimen.

The application of different settings for parameter configuration shows that order pattern analysis—as represented by the electroencephalographic parameters PeEn, ORR, and OPC—separates consciousness from unconsciousness better than ApEn. On the basis of data from study B (evaluation study), prediction probability analysis of PeEn, ORR, and OPC results in P  K= 0.78 if a high cutoff frequency f  highof 30 Hz is applied, and P  K= 0.83 with a maximal high cutoff frequency f  highof 70 Hz.

These results are similar to the P  Kvalues of the spectral parameter weighted spectral median frequency, using the same studies as for the current analysis (P  K= 0.82 using data from study A, P  K= 0.79 using data from study B with f  highof 30 Hz and P  K= 0.82 with f  highof 49 Hz).4Therefore, one may speculate that nonlinear measures do not identify additional crucial information leading to significantly better separation of consciousness and unconsciousness. This may be in part due to signal distortions in the measurement chain of the electroencephalogram. On the other hand, anesthesia-induced unconsciousness may not only be due to cortical effects of anesthesia, but also reflect subcortical mechanisms—which may or may not be detected by changes of cortical electrical activity. In contrast to the presented nonlinear parameters, weighted spectral median frequency considers signal frequencies above 8 Hz only,4and this may cause a drawback of the parameter performance during deeper levels of anesthesia. With increasing levels of anesthesia, the electroencephalogram does not only show more regularity, but frequencies are also decreased. Therefore, the inclusion of frequencies in the delta and theta bands, i.e. , below 8 Hz, may be essential.

On the basis of a similar data set from study A, a multiparametric indicator of consciousness from the electroencephalographic parameters weighted spectral median frequency and ApEn and on two wavelet coefficients of auditory evoked potentials was developed previously.2This indicator reached a P  Kof 0.87, which is similar to P  K= 0.85 (f  high= 30 Hz) and P  K= 0.87 (f  high= 49 Hz) as obtained for PeEn, ORR, and OPC. Whereas P  Kvalues are similar, the basis of these values is different. The multiparametric indicator includes information from the auditory evoked potential, which reflects not only a cortical but also a subcortical neuronal pathway. Therefore, it may reflect not only cortical but also subcortical effects of anesthetics. Although this approach may be helpful, because it includes monitoring of important effect sites of anesthesia, it adds requirements and may complicate consciousness monitoring. First, the auditory pathway of patients must be grossly intact, i.e. , deafness or severe hardness of hearing may limit the value of anesthesia monitoring. Second, additional equipment is required to produce repeated auditory stimuli. This may increase cost and limit acceptance by the clinical user. This potential drawback may be overcome by the use of nonevoked, spontaneous electrical activity of the brain, the electroencephalogram. With the tested methods of signal analysis, comparable P  Kvalues were obtained. This underlines the potential of the new order pattern analysis in a practical application for electroencephalogram-based monitoring.

Furthermore, parameters of order pattern analysis are largely independent of the upper frequency limit f  high, i.e. , the classic electroencephalographic frequency band up to 30 Hz contains sufficient information to separate consciousness from unconsciousness. This may be an advantage because inclusion of frequencies above 30 Hz, i.e. , analysis of the gamma band, bears the risk that the resulting index does not primarily reflect activity of the main target organ of anesthesia, the brain. In particular, if electrodes are positioned on the forehead, gamma activity is overlapped by electromyogram of the frontal muscle. Therefore, such a parameter may also be a surrogate measure (muscle activity) of the hypnotic component of anesthesia. As a consequence, a patient who is fully awake during neuromuscular block may not be detected as “awake” if no electromyogram is detected.34 

In addition, P  Kof PeEn is independent not only of f  highbut also of its embedding dimension (fig. 3B). This may indicate that the parameter is robust against more or less unknown underlying characteristics of electroencephalographic signals, and therefore PeEn represents a “state-of-the-art” electroencephalographic parameter to distinguish consciousness from unconsciousness during general anesthesia. Nevertheless, it is unknown to which degree the electroencephalogram contains low-dimensional dynamics,25,26and therefore a conclusion about determinism and dimensionality of the electroencephalogram should not be drawn, even if an “optimal” embedding dimension for a specific nonlinear parameter was found.

The current investigation shows that nonlinear measures of the regularity of an electroencephalographic signal are not equally useful for the separation of consciousness from unconsciousness. It is important to which degree such a parameter is influenced by different sources of interference, high dimensionality, and nonstationarity of the signal. Order pattern analysis seems to be a beneficial approach. It leads to parameters that are largely independent of settings (e.g. , high cutoff frequency and embedding dimension) and perform equally well on both training and evaluation data sets for separation of consciousness from unconsciousness.

Although ApEn is less adequate to separate consciousness from unconsciousness, it shows a monotone relation between parameter values and anesthetic concentration in phases of increasing anesthetic concentrations until electroencephalographic burst suppression.10,13,14 

The challenging selection of data immediately before and after loss and return of consciousness leads to analysis periods that are very close both in time and in drug concentration but are characterized by a different clinical patient status. Consideration of four transitions between consciousness and unconsciousness per patient includes evaluation of intraindividual parameter stability in P  Kstatistics and completes interindividual assessment. In principle, the analysis of repeated measurements from a single patient may induce nonindependent data. In the current analysis, no statistical compensation for possibly dependent data was performed, because measurements from identical clinical states were from distinct time points. In addition, this approach keeps statistical results comparable with those of previous investigations.2,4The results support the applicability of order pattern analysis in electroencephalographic monitoring in anesthesia. In the next step, analysis of order patterns must be performed not only for the two states, consciousness and unconsciousness, but for the entire range from light sedation to general anesthesia. It remains to be examined whether ApEn and order pattern analysis, in particular PeEn, can be combined into an indicator of depth of anesthesia.

The authors thank the members of the research group Electroencephalography and Neurophysiology of the Department of Anesthesiology, Technische Universität München, Germany, and the research group knowledge-based signal processing for medical applications of the Institute of Information Technology, University Duisburg-Essen, Campus Duisburg, Germany, for their help.

1.
Thakor NV, Tong S: Advances in quantitative electroencephalogram analysis methods. Annu Rev Biomed Eng 2004; 6:453–95
2.
Schneider G, Hollweck R, Ningler M, Stockmanns G, Kochs E: Detection of consciousness by electroencephalogram and auditory evoked potentials. Anesthesiology 2005; 103:934–43
3.
Schwilden H, Stoeckel H: Investigations on several EEG-parameters as indicators of the state of anaesthesia the median: A quantitative measure of the depth of anaesthesia. Anasth Intensivther Notfallmed 1980; 15:279–86
4.
Jordan D, Stockmanns G, Kochs E, Schneider G: Median frequency revisited: An approach to improve a classical electroencephalographic parameter for the separation of consciousness from unconsciousness. Anesthesiology 2007; 107:397–405
5.
Grassberger P, Proccacia I: Measuring the strangeness of strange attractors. Physica 1983; 9D:189–208
6.
Lai YC, Osorio I, Harrison MA, Frei MG: Correlation-dimension and autocorrelation fluctuations in epileptic seizure dynamics. Phys Rev E Stat Nonlin Soft Matter Phys 2002; 65:031921
7.
Lempel A, Ziv J: On the complexity of finite sequences. IEEE Trans Inf Theory 1976; 22:75–81
8.
Fell J, Roschke J, Mann K, Schaffner C: Discrimination of sleep stages: A comparison between spectral and nonlinear EEG measures. Electroencephalogr Clin Neurophysiol 1996; 98:401–10
9.
Pincus SM, Gladstone IM, Ehrenkranz RA: A regularity statistic for medical data analysis. J Clin Monit 1991; 7:335–45
10.
Bruhn J, Röpcke H, Hoeft A: Approximate entropy as an electroencephalographic measure of anesthetic drug effect during desflurane anesthesia. Anesthesiology 2000; 92:715–26
11.
Widman G, Schreiber T, Rehberg B, Hoeft A, Elger CE: Quantification of depth of anesthesia by nonlinear time series analysis of brain electrical activity. Phys Rev E 2000; 62:4898–903
12.
Ferenets R, Lipping T, Anier A, Jantti V, Melto S, Hovilehto S: Comparison of entropy and complexity measures for the assessment of depth of sedation. IEEE Trans Biomed Eng 2006; 53:1067–77
13.
Jordan D, Schneider G, Hock A, Hensel T, Stockmanns G, Kochs EF: EEG parameters and their combination as indicators of depth of anaesthesia. Biomed Tech (Berl) 2006; 51:89–94
14.
Bruhn J, Röpcke H, Rehberg B, Bouillon T, Hoeft A: Electroencephalogram approximate entropy correctly classifies the occurrence of burst suppression pattern as increasing anesthetic drug effect. Anesthesiology 2000; 93:981–5
15.
Bandt C, Pompe B: Permutation entropy: A natural complexity measure for time series. Phys Rev Lett 2002; 88:174102
16.
Jordan D, Schneider G, Kochs EF: EEG permutation entropy separates consciousness from unconsciousness during anesthesia (abstract). Anesthesiology 2006; 105:A1551
17.
Jordan D, Stockmanns G, Kochs EF, Schneider G: Permutation entropy of the EEG indicates increase and decrease of the anesthetic level (abstract). Anesthesiology 2007; 107:A800
18.
Groth A: Visualization of coupling in time series by order recurrence plots. Phys Rev E 2005; 72:046220
19.
Schneider G, Gelb AW, Schmeller B, Tschakert R, Kochs E: Detection of awareness in surgical patients with EEG-based indices: Bispectral index and patient state index. Br J Anaesth 2003; 91:329–35
20.
Tunstall ME: Detecting wakefulness during general anaesthesia for caesarean section. BMJ 1977; 1:1321
21.
Brice DD, Hetherington RR, Utting JE: A simple study of awareness and dreaming during anaesthesia. Br J Anaesth 1970; 42:535–42
22.
Stockmanns G, Ningler M, Omerovich A, Kochs E, Schneider G: NeuMonD: A tool for the development of new indicators of anaesthetic effect. Biomed Tech 2007; 52:96–101
23.
Jordan C, Weller C, Thornton C, Newton DEF: Monitoring evoked potentials during surgery to assess the level of anaesthesia. J Med Eng Technol 1995; 19:77–9
24.
Wolf A, Swift JB, Swinney HL, Vastano J: Determining Lyapunov exponents from a time-series. Physica 1985; 16:285–317
25.
Faure P, Korn H: Is there chaos in the brain? I: Concepts of nonlinear dynamics and methods of investigation. C R Acad Sci III 2001; 324:773–93
26.
Korn H, Faure P: Is there chaos in the brain? II: Experimental evidence and related models. C R Biol 2003; 326:787–840
27.
Marwan N, Romano C, Thiel M, Kurths J: Recurrence plots for the analysis of complex systems. Phys Rep 2007; 438:237–329
28.
Smith WD, Dutton RC, Smith N: Measuring the performance of anesthetic depth indicators. Anesthesiology 1996; 84:38–51
29.
Davison AC, Hinkley DV: Bootstrap methods and their application, Cambridge Series in Statistical and Probabilistic Mathematics. Cambridge, Cambridge University Press, 1997, pp 191–255
Cambridge
,
Cambridge University Press
30.
Shaffer JP: Multiple hypothesis testing. Annu Rev Psychol 1995; 46:561–76
31.
Myles PS, Leslie K, McNeil J, Forbes A, Chan MT: Bispectral index monitoring to prevent awareness during anaesthesia: The B-Aware randomised controlled trial. Lancet 2004; 363:1757–63
32.
Rampil IJ: A primer for EEG signal processing in anesthesia. Anesthesiology 1998; 89:980–1002
33.
Zhang XS, Roy RJ, Jensen EW: EEG complexity as a measure of depth of anesthesia for patients. IEEE Trans Biomed Eng 2001; 48:1424–33
34.
Messner M, Beese U, Romstock J, Dinkel M, Tschaikowsky K: The bispectral index declines during neuromuscular block in fully awake persons. Anesth Analg 2003; 97:488–91